Avaya 03-300430 Benutzerhandbuch

Seite von 2574
Communication Manager Maintenance-Object Repair Procedures
1944 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
e. See 
on page 1240 for a description of this test.
Notes:
a. See 
on page 880 for a description of this 
test.
b. See 
on page 1134 for a description of this test.
c. See 
on page 1240 for a description of this test.
Analog Ring Generator Initialization Test (#117)
The Analog Ring Generator Initialization test sends a request to the active TN768, TN780, 
TN2182 Tone-Clock or TN2312AP IPSI circuit pack’s Tone-Clock circuit to monitor the voltage. 
The Tone-Clock responds with an error if the ringing voltage falls too low.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Analog Ring Generator Initialization test (#117)
X
X
ND
Analog Ring Generator Query test (#118)
X
X
ND
Single-Carrier Cabinet Power Query test (#79) (
)
X
X
ND
Emergency Transfer Query test (#124) (
X
X
ND
External Alarm Lead Query test (#120) (
)
X
X
ND
Table 715: Test #117 Analog Ring Generator Initialization Test 
Error
 Code
Test
 Result
Description / Recommendation
1
1000
1001
1003
1115
2012
2100
ABRT
The system software is unable to determine the active Tone-Clock circuit 
pack, unable to allocated the resources necessary to run the test, or 
unable to send a down link message.
1. Wait for the green LED on the active Tone-Clock to go out.
2. Use status port-network to determine the active Tone-Clock 
circuit pack.
3. Rerun the test. If the test aborts again, see 
 1 of 2