Avaya 03-300430 Benutzerhandbuch
Communication Manager Maintenance-Object Repair Procedures
2034 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
TPN Test (#779)
This test is nondestructive.
This test queries the SNC circuit pack for status of the ROM and internal RAM background tests
for the TPN microcontroller.
This test queries the SNC circuit pack for status of the ROM and internal RAM background tests
for the TPN microcontroller.
Table 743: TEST #779 TPN Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message
necessary to run this test.
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302
ABRT
Software received unexpected message data from the SNC circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303
ABRT
The SNC circuit pack responded that the software test requested is not
valid.
valid.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABRT
SNC circuit pack responded that it is not able to run the test requested by
software.
software.
1. Retry the command at 1-minute intervals up to 3 times.
1 of 2