Avaya 03-300430 Benutzerhandbuch
Communication Manager Maintenance-Object Repair Procedures
2254 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
procedures.
b. Error Type 1: the IPSI or Tone-Clock circuit pack may have a clock at the edge of its
specified frequency. This can cause Expansion Interface circuit packs and SNI circuit packs
to go out-of-frame or report no-neighbor conditions. This can is turn cause EPNs,
Expansion Archangel Links (EALs), Remote Neighbor Links (RNLs), and/or Local Neighbor
Links (LNLs) to go down. When this error is alarmed, Clock Health Inquiry test (#46) will fail
with an Error Code of 1.
to go out-of-frame or report no-neighbor conditions. This can is turn cause EPNs,
Expansion Archangel Links (EALs), Remote Neighbor Links (RNLs), and/or Local Neighbor
Links (LNLs) to go down. When this error is alarmed, Clock Health Inquiry test (#46) will fail
with an Error Code of 1.
1. Replace the IPSI or Tone-Clock circuit pack identified in the error log. See
c. Error Type 18: the indicated Tone-Clock circuit has been made unavailable using busyout
tone-clock location. It only applies to systems with the high- or critical-reliability
option administered, because only a standby Tone-Clock circuit may be made busy by that
command. To resolve this error, execute release tone-clock location for the
command. To resolve this error, execute release tone-clock location for the
alarmed circuit pack.
d. Error Type 130: the circuit pack has been removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
769 (
Any
Clock Circuit Status
inquiry (#148)
MAJ‡
ON
test tone-clock location sh r
10
1025 (
)
Any
Clock Slip
inquiry(#149)
test tone-clock location sh
1281
1282 (
)
Any
None
MIN
OFF
1537
Any
Clock PPM inquiry
(#150)
test tone-clock location sh
2049 (
)
Any
Standby Reference
Health Check test
(#651)
MAJ
ON
test tone-clock location
2305 (
0
None
WRN
OFF
1. As a general rule, any on-board errors against the TDM Bus Clock should be resolved before pursuing any
other errors against PNC components. Off-board clock errors may be caused by other board errors, and
should be addressed after on-board errors have been resolved.
should be addressed after on-board errors have been resolved.
2. Major or Minor alarms on this MO may have been downgraded to Warning based on the values in
set
options
.
Table 806: TDM Bus Clock Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
1
Test to Clear Value
2 of 2