Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly perform the 
conferencing function.
Table 101: Test #7 Conference Circuit Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run test are not available. The port may be 
busy with a valid call.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If the 
port is active, wait until it is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If the 
port is active, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABRT
Test disabled by administration. This only applies to analog stations.
1. To enable the test for the analog station being tested, enter change 
station extension and enter y in the Test field.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This 
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated by using other port tests and by 
examining station, trunk, or external wiring.