Avaya 03-300430 Benutzerhandbuch

Seite von 2574
ANL-16-L (16-Port Analog Line)
Issue 1 June 2005
385
 
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this 
ringing is disturbing the customer or the terminal equipment, it should be disabled in the Tests 
field of the change station extension screen. Be aware that this action will also disable 
Tests #6, 7, 161, and 35.
Error Log Entries and Test to Clear Values
Table 112: 16-Port Analog Line Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location sh r 1
1(
40960 
40975 
40977
none
15(
)
Any
Audits and Updates 
(#36)
18
0
busyout station 
extension
WRN
ON
release station extension
)
None
WRN
ON
test port location sh
)
40973
none
Station Present (#48)
WRN
OFF
test port location sh r 2
769
Battery Feed test 
(#35)
MIN
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON
test port location sh r 2
1025
Looparound (#161)
MIN
WRN
ON
test port location l r 2
1281
Conference test (#7)
MIN
WRN
ON
test port location l r 2
1537
NPE Crosstalk (#6)
MIN
WRN
ON
test port location l r 2