Avaya 03-300430 Benutzerhandbuch

Seite von 2574
Communication Manager Maintenance-Object Repair Procedures
512 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
i. Error Type 3073: Service State Audit attempt failed. See 
.  Calls can be received but not placed until the test passes and the trunk state 
returns to In-Service.
1. Check the trunk’s status (status trunk grp#/mem#).
j. Error Type 3585: ISDN RESTART message received.  Active calls have been dropped.
The following Aux Data values (Error Type 3585 only) below represent the trunk’s ISDN call 
state at the time Error 3585 occurred.  This information can be useful if users report 
dropped calls on the ISDN-PRI trunks.
k. Error Type 3841: the far end rejected an ATM CES trunk selected by the near end 10 times.  
The ATM CES trunk may not be administered on the far end.
1. Get the physical name of the ATM trunk by noting the decimal number in the Aux Data 
field.
2. Check administration for the named trunk on the far end.
3. If problems persist, then busyout the ATM trunk to take it out of the hunt group.
The WARNING alarm retires automatically whenever a called endpoint answers an 
outgoing or incoming call that uses the alarmed trunk.
Aux  Data Description
0
An idle trunk received a restart.
10
An ISDN RESTART from the far end has unexpectedly cleared a call in the 
ACTIVE state (call stable, parties talking).
260 263 
An ISDN RESTART from the far end has unexpectedly cleared a RINGING call.
9
265
An ISDN RESTART from the far end has unexpectedly cleared a call before the 
call entered the RINGING state.
11 
12 
19 
531 267 
268
An ISDN RESTART from the far end has unexpectedly cleared a call that was 
already in the process of clearing.
If this condition occurs frequently, the far end may be trying  to clear trunks that 
appear to be in the “hung” state.