DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
963
 
2053
ABRT
At least one of the following errors is found on the DS1 circuit pack:
1281 – Loss of signal
1793 – Blue alarm
2049 – Red alarm
2305 – Yellow alarm
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the 
procedures given in the 
or 
documentation for the listed error types.
FAIL
The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration screen 
screen matches the trunk type administered on far-end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, see 
3. Retry the test at 1-minute intervals up to 5 times.
PASS
The trunk can be seized for an outgoing call.
Table 331: Test #314 DS1 CO Dial Tone Seizure Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation