DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
963
2053
ABRT
At least one of the following errors is found on the DS1 circuit pack:
●
1281 – Loss of signal
●
1793 – Blue alarm
●
2049 – Red alarm
●
2305 – Yellow alarm
●
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the
or
on page 2374 maintenance
documentation for the listed error types.
FAIL
The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration screen
screen matches the trunk type administered on far-end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, see
3. Retry the test at 1-minute intervals up to 5 times.
PASS
The trunk can be seized for an outgoing call.
Table 331: Test #314 DS1 CO Dial Tone Seizure Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
3 of 3