3.6.3  Alarms Acknowledged within the Abort Window 
If the end user acknowledges an alarm within the Abort Window: 
 
The alarm output is silenced. 
 
No alarm, restoral, or cancel reports are sent. 
 
No alarm, restoral, or cancel reports are entered in the control 
panel event log. 
3.6.4  At the End of the Alarm Abort Window 
If no user acknowledges the alarm within the Alarm Abort Window, 
the control panel sends the appropriate alarm reports. 
3.7 Cancel 
Report 
and Cancel Window 
If a user acknowledges an alarm after the Abort Window expires, 
but before Bell Time expires, the control panel sends a Cancel 
Report. The Cancel Window starts when the alarm is sent and 
stops when the Alarm Bell timer expires or a user acknowledges 
an alarm. 
3.8 Duress 
Alarm 
This feature allows any passcode with the Send Duress permission 
enabled to always send a Duress Alarm event upon entry. The 
Duress Alarm feature allows an installation to allocate unique 
passcodes as the main duress passcodes for all users.  
Additionally, when the SIA CP-01 compliant Duress Alarm option is 
enabled, the Passcode +1 and +2 options are disabled. 
3.9 Swinger 
Shutdown 
This feature allows for a
 control panel to automatically bypass a point 
that reports two or more alarm or trouble events within the same arm 
cycle. The maximum number of faults allowed on a point is called the 
Swinger Count. This value was set by the installer.