Monessen Hearth GLX18 Benutzerhandbuch

Seite von 40
6
14D2099
PROPANE / LPG
Note:  An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
MANUAL / T-STAT PRESSURE
MILLIVOLT PRESSURE
Regulator Pressure Setting:
10" w.c.
Regulator Pressure Setting:
10" w.c.
Gas Inlet Pressure:
Maximum 13" w.c.
Gas Inlet Pressure:
Maximum 13" w.c.
Minimum 11" w.c.
Minimum 11" w.c.
NATURAL GAS
MANUAL / T-STAT PRESSURE
MILLIVOLT PRESSURE
Regulator Pressure Setting:
3" w.c.
Regulator Pressure Setting:
3.5" w.c.
Pilot Regulator:
3.5" w.c.
Gas Inlet Pressure:
Maximum 10 
1
/
2
" w. c.
Gas Inlet Pressure:
Max. 10 
1
/
2
" w. c.
Minimum 5" w.c.
Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF
-
All gas to the gas logs is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
LOW
-
Minimum gas rate — front burner provides a realistic glow on the center log.
HI
-
Maximum gas rate — front burner provides a realistic glow on the center log, plus the rear burner
provides a pleasing yellow flame.
Gas Rate
Model Number
Control
Max BTU/Hr
Min BTU/Hr
DLX18NV, GLX18NV
Manual
26,000
16,000
  DLX24/28NM, GLX24/28NM
Manual
32,000
19,000
DLX18NT, GLX18NT
T-Stat
26,000
16,000
DLX24/28NT
Milli-Volt
26,000
20,000
DLX18NV, GLX18NV
Milli-Volt
26,000
17,000
DLX24/28NV, GLX24/28NV
Milli-Volt
32,000
22,000
Gas Rate
Model Number
Control
Max BTU/Hr
Min BTU/Hr
DLX18PV, GLX18PV
Manual
22,000
14,000
DLX24/28PM, GLX24/28PM
Manual
33,000
19,000
DLX18PT, GLX18PT
T-Stat
26,000
16,000
DLX24/28PT
Milli-Volt
28,000
20,000
DLX18PV, GLX18PV
Milli-Volt
22,000
17,000
DLX24/28PV, GLX24/28PV
Milli-Volt
33,000
22,000
PRODUCT FEATURES 