EYF Series Unvented Gas Log Set
FLAME APPEARANCE
FP2501
manual pilot flame
FP2273
pilot bad flame
FP2272
pilot correct flame
Flames from the pilot, front and rear burner should be visually checked as soon as the 
heater is installed.
 In addition, periodically check the flames visually during operation.
ChECk ThE PILOT fLAME
The pilot flame must always be present when the heater is in operation. It should just 
touch the top of the thermocouple tip for natural. Refer to Figures 29 & 30 for correct pilot 
flame. 
If the pilot flame does not touch the thermocouple, then the main burner cannot function 
reliably. Refer to Figures 29 & 30 for incorrect shape of pilot flame.
Figure 29 - 
Millivolt Control Pilot Flame Appearance
Thermocouple 
for Natural Gas
Thermocouple 
for LP
FP7
Thermocouple 
for Natural Gas
Thermocouple 
for LP
FP73
MILLIVOLT CONTROL
Correct Pilot Flame Appearance
Incorrect Pilot Flame Appearance
MANUAL  & HI/LO CONTROL
Thermocouple 
for Natural Gas
Thermocouple 
for LP
Thermocouple 
for Natural Gas
Thermocouple 
for LP
FP50
Correct Pilot Flame Appearance
Incorrect Pilot Flame Appearance
Figure 30 - 