Monessen Hearth EYF18 Benutzerhandbuch

Seite von 32
19
65D1009
EYF Series Unvented Gas Log Set
FLAME APPEARANCE
In normal operation at full rate after 15 minutes, the following flame appearances should 
be observed:
The left and right flames should be yellow and extend 1" to " above the log top surfaces. The 
yellow flames should not contact the logs.
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the 
fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create 
drafts that alter flame patterns. Sooting and improper burning will result.
During  manufacturing,  fabricating  and  shipping,  various  components  of  this  appliance  are 
treated with certain oils, films or bonding agents. These chemicals are not harmful, but may 
produce annoying smoke and smells as they are burned off during the initial operation of the 
appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary 
occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. 
Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors 
remaining after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot 
outages and severe sooting outside the fireplace.
LO
HI
OFF
ON
I
G
N
LG717
EYF flame height
Figure 31 - 
Correct Burner Flame Appearance
LG717