Monessen Hearth EYF18 Benutzerhandbuch

Seite von 32
3
65D1009
EYF Series Unvented Gas Log Set
OPERATING INSTRUCTIONS and MAINTENANCE
MATCh LIGhTING INSTRUCTIONS
1.  Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
.  Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo 
button, light a match and hold the flame to the end of the pilot and ignite the pilot.
3.  After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot 
access.
4.  Call a qualified service technician for repair or replacement of the piezo ignitor.
W
ARNING
Turn  off  heater  and  allow  to  cool  before 
cleaning.
Disconnect  electrical  power  (optional  blower) 
before cleaning or servicing.
MAINTENANCE
Remove logs carefully by holding gently at each end. Gloves are recommended to prevent skin 
irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Refer 
to Log Placement, Pages 15-17 for correct log placement.
PERIODIC CLEANING
 - Refer to the parts diagram for location of items discussed 
below.
•  
Do not use cleaning fluid to clean logs or any part of heater.
•  
Brush logs with soft bristle brush or vacuum with brush attachment.
•  
Vacuum loose particles and dust from the front and rear burner, control and piezo covers 
and grate weldment.
•  
Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush, 
or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor 
combustion.
•  
External case should be dusted and wiped with a wet soapy cloth.
ANNUAL CLEANING/INSPECTION
 - Refer to the parts diagram for location of 
items discussed below.
•  
Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush or 
pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor com-
bustion.
•  
Inspect and clean all burner ports.
•  
Inspect ODS pilot for operation and accumulation of lint at air intake holes.
•  
Verify flame pattern and log placement for proper operation.
•  
Verify smooth and responsive ignition of main burner and rear burner.