Vermont Casting SDDVTCVG Benutzerhandbuch

Seite von 52
40
Stardance Direct Vent/Natural Vent Gas Heater
20012734
 
Conversion to Natural Gas
 
 
 
 
 
 Input (BTU/h)
 
Model 
Kit # 
Orifice 
Part # 
Minimum   Maximum
 
SDDVT 
20012903 
  
 
20,000   
 
 
  SDDVTC 
20012905 
#38 / .101” 
20009310 
22,000
 
  28,000
Table 2.  Injector Orifice Size Matrix
 
Conversion to LP
 
 
 
 
 
 Input (BTU/h)
 
Model 
Kit # 
Orifice 
Part # 
Minimum   Maximum
 
SDDVT 
20012735 
  
 
20,000   
 
 
  SDDVTC 
20012904 
#53 / .0595”  20007347 
22,000
 
  28,000