Heat & Glo LifeStyle CERONA-36 Benutzerhandbuch

Seite von 62
Heat & Glo  • Cerona-36, Cerona-42  •  2106-900  Rev. A  •  6/06
48
Maintaining and Servicing Appliance
15
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service
technician should perform an appliance checkup at the beginning of each heating season.
WARNING
Annual inspection by qualified technician recommended.
Check:
• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Condition of logs.
• Condition of firebox.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and fittings.
• Obstructions of termination cap.
Clean:
• Glass
• Air passageways, grilles,
control compartment
• Burner, burner ports
Risk of:
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours
operation.  Longer operation without
cleaning glass may cause a permanent
white film on glass.
CAUTION
When cleaning glass door:
• Avoid striking, scratching or slamming glass.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white film.
• Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and
ALLOW TO COOL.
• Remove and clean glass assembly.
• Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
Risk of injury or property damage.
Before servicing:
• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.
After servicing:
• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for servicing.
WARNING
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
WARNING
• Combustible materials blocking cap may ignite.
• Restricted air flow affects burner operation.