Paradox Hellas S.A. EVO96 Benutzerhandbuch

Seite von 36
16 EVO96 
Option [6]: Add Tolerance Window to Schedule
When option [6] is ON, the Schedule Tolerance Window feature is enabled. This feature 
extends a user’s scheduled access period through an Access Control door by the amount 
programmed by your installer. For example, if the user’s assigned schedule for the door is 
Monday to Friday from 9:00 a.m. to 5:00 p.m., and your installer sets the “Tolerance 
Window” at one hour, the user with the “Schedule Tolerance Window” enabled will be able 
to enter and exit one hour before and after their scheduled time for that door.
Option [7]: Code Follows Schedule
When option [7] is ON, users can use their access codes only during their scheduled 
hours assigned in step 8 in section 6.6.1 on page 13. When the option is OFF, users can 
use their access codes at any time.
Option [8]: Card to Unlock and Code to Disarm 
Option [8] functions only if option [2] in section 6.8 is OFF. When option [8] is ON, a user 
can use an Access Control card to unlock an armed Access Control door, however the 
user must enter a user access code to disarm the armed area. When option [8] is OFF, a 
user can gain access to an Access Control door only if the door’s area(s) is already 
disarmed.
For option [8] to function in the ON position, option [5] “Arm Only” in the 
User Options must be disabled (refer to section 6.7 on page 14).