Vermont Casting 2468 Benutzerhandbuch

Seite von 28
10
Dutchwest Natural Vent Gas Heater
30002008
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the 
firebox, to confirm that you have the appropriate firebox 
for the type of fuel to be used. The Dutchwest may be 
converted from one gas to another using the appropri-
ate Fuel Conversion Kit listed on Page 23.
This appliance should only be connected 
by a qualified gas technician. Test to 
confirm manifold pressures as specified 
below.
The Dutchwest Heater and its individual shutoff 
valve must be disconnected from the gas supply 
piping during any pressure testing of that system 
at test pressures in excess of 1/2 psig (3.5 kPa).
The Dutchwest Heater must be isolated from the 
gas supply piping system by closing its indi-
vidual manual shutoff valve during any pressure 
testing of the gas supply piping system at test 
pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove 
and the supply.
In order to connect Natural Gas, use a fitting with 
3/8” NPT nipple on the valve side and 1/2” natural 
gas supply line with an input of 28,000 BTUs at 
a manifold pressure of 3.5” and a minimum inlet 
supply pressure of 5.5” w.c.
In order to connect Propane, use a fitting with    
3/8” NPT nipple on the valve side and 1/2” pro-
pane gas supply line with an input of 26,000 
BTUs at a manifold pressure of 10.0” and a mini-
mum inlet supply pressure of 11.0” w.c.
In the U.S.; Gas connection should be made in ac-
cordance with current National Fuel Gas Code, ANSI 
Z223.1/NFPA 54. Since some municipalities have addi-
tional local codes, be sure to consult you local authority.
In Canada; consult the local authority and CSA-B149.1 
installation code.
Connect the gas supply and test for leaks. Use a 50/50 
solution of liquid soap and water to test for leaks at gas 
fittings and joints. Apply water/soap solution with brush 
only - do not over apply.  NEVER test with an open 
flame. 
Light the pilot according to the directions on 
Page 14, before going to the next step.
CAUTION
ST777
Dutchwest
nv
decorative pipe
template
6/20/03   djt
B-vent Pipe
Decorative 
Pipe 7FSSK
Bracket
ST374
Fig. 18  Install decorative pipe over the B-vent pipe.
Attach the first section of venting to the B-vent adapter. 
Depending on the length of the individual venting 
sections and the lengths of the decorative pipe, you 
may need to slip the decorative pipe over the venting 
sections before attaching upper sections to lower ones. 
The sections of decorative pipe should be oriented with 
their seams (if any) toward the wall; sections usually 
do not need to be fastened at each joint, other than slip 
sections. The decorative pipe need not be fastened to 
the locating bracket on the stove. If the layout includes 
a slip section, this should be the last section of pipe vis-
ible in the room at the ceiling. Refer to Page 7, Figure 6 
for details on joining the decorative pipe at the ceiling.