III.  FURNACE SPECIFICATIONS 
 
MODEL 
 
 
 
OMC-70 
 
 
 
GMC-85 
 
HEAT INPUT RATE (BTUH) 
 85,000 
 
 
 
 85,000 
HEATING 
CAPACITY 
(BTUH) 
 
71,000     
69,700 
BURNER NOZZLE  (GPH X 
 
 
ANGLE, HOLLOW CONE)             0.65X80A 
 
 
              -------  
BURNER ORIFICE-NAT. GAS 
 --------- 
 
 
           #17 DMS 
BURNER ORIFICE-PROP. GAS       --------- 
 
 
           #36 DMS 
OIL PUMP PRESSURE (PSIG) 
    100                                                    ------- 
GAS SUPPLY PRESSURE (IN.W.G.) 
      MINIMUM REQUIRED                                                                             
PROPANE                                ---------                                                    11 
NATURAL                               ---------                                                   4.5 
     MAXIMUM ALLOWED 
           PROPANE                                 ---------                                                   13.9 
           NATURAL                                ---------                                                   13.9 
GAS MANIFOLD PRESSURE (IN. W.G.) 
           PROPANE                                 ---------                                                10 + 0.3 
           NATURAL                                ---------                                                3.5 + 0.3    
VENT PIPE SIZE (INCHES)         4   
 
 
 
      4 
DESIGN TEMPERATURE RISE (°F)     85  
 
 
 
      85 
SEASONAL EFFICIENCY  
(AFUE*, %)                                             84   
 
 
 
      82 
 
*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE 
LOSSES. 
 
ELECTRICAL RATINGS AND SETTINGS: 
ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE 
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS 
TOTAL RATED CURRENT (AMPS): 11.3 (OMC), 6.81 (GMC) 
NOMINAL HEAT ANTICIPATOR SETTING  -- 0.2 mA (OMC), 0.8 mA (GMC) 
 
DIMENSIONS & WEIGHTS: 
CABINET: WIDTH - 18 IN., DEPTH - 24 IN., HEIGHT - 57 IN. 
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN. 
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.  
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN. 
FILTER QUANTITY & SIZE: (2) @ 17 ¾ IN. x 13 ¾ IN. x 1 IN. EA. 
APPROXIMATE SHIPPING WEIGHT: 240 LBS. 
 
PRODUCT LISTED UNDER UL FILE NUMBER -- MP3241