II.  FURNACE SPECIFICATIONS 
 
CHB1 SERIES 
 
MODEL NO. 
CHB1-50 
CHB1-75 
CHB1-100 
CHB1-125 
BTU/HR INPUT 
50,000 
75,000 
100,000 
125,000 
BTU/HR OUTPUT 
47,000 
72,000 
94,000 
116,000 
 
 
 
 
 
HT. OF CASING 
44-1/4” 
44-1/4” 
44-1/4” 
44-1/4” 
WIDTH OF CASING 
17” 
17” 
21” 
24” 
DEPTH OF CASING 
27-1/2” 
27-1/2” 
27-1/2” 
27-1/2” 
WARM AIR OUTLET 
15 x 18 
15 x 18 
19 x 18 
22 x 18 
RETURN AIR INLET 
25 x 16 
25 x 16 
25 x 16 
25 x 16 
 
 
 
 
 
DIA. OF FLUE 
2” 
2” 
3” 
3” 
DIA. OF COMBUSTION 
AIR INTAKE 
2” 
2” 
3” 
3” 
 
 
 
 
 
CFM @ .2” & .5” w.c. 
EXTERNAL STATIC PRESSURE 
.2”   .5” 
.2”   .5” 
.2”   .5” 
.2”   .5” 
 
 
 
 
 
@HI SPEED 
1100   860 
1600   1380 
1940   1700 
2770   2060 
@MH SPEED 
1000   720 
1250   1150 
1720   1540 
1800   1700 
@ML SPEED 
--         -- 
1030   930 
1530   1380 
1730   1600 
@LO SPEED 
610    420 
820    700 
1340   1220 
1670   1550 
 
 
 
 
 
TEMPERATURE RISE 
70 
70 
70 
70 
BLOWER MOTOR HP 
.20 
.41 
.50 
.75 
NO. OF SPEEDS 
RUN CAPACITOR 
10 mfd 
10 mfd 
10 mfd 
10 mfd 
LARGEST RECOMMEDED 
AIR CONDITIONER 
2 Ton 
3.5 Ton 
4 Ton 
5 Ton 
SIZE OF FILTERS 
24-3/4” x 15-3/4” 
24-3/4” x 15-3/4” 
24-3/4” x 15-3/4” 
24-3/4” x 19-3/4” 
 
 
NOTES: 
1.  BTU output based on annual fuel utilization efficiency rated by manufacturer. 
2.  On all outlet and inlet dimensions, the first dimension is width. 
3.  To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is 
required.