Goodman Mfg GMVM96 Benutzerhandbuch

Seite von 12
P
RoDucT
 s
PeciFicATions
P
RoDucT
 s
PeciFicATions
4 www.goodmanmfg.com 
SS-GMVM96
gMVM96 D
iMensions
M
iniMuM
 c
leARAnces
 
To
 c
oMbusTible
 M
ATeRiAls
Position
Sides
Rear
Front
Bottom
Flue
Top
Upflow
0”
0”
3”
C
0”
1”
Horizontal
6”
0”
3”
C
0”
6”
C = If placed on combustible floor, the floor MUST be wood ONLY.
Notes
•  For servicing or cleaning, a 24” front clearance is required.
•  Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.
•  In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
28¾
19⅞
RIGHT SIDE VIEW
LEFT SIDE VIEW
22 ¹/₁₁ 
FOLDED FLANGES
23 ⁹/₁₆
UNFOLDED FLANGES
FRONT VIEW
FOLDED FLANGES
UNFOLDED FLANGES
D
E
11¾
30¼
¾
¾
30¼
11¾
32¹³/₁₁
19³/₁₁
24₁/₁₁
2¹¹/₁₁
2¹/₁₁
19³/₁₁
¾
21¼
2⅝
7⅜
1⅝
4⅛
16⅝
2⅝
27⅛
6⅛
Model
W
D
H
A
B
C
D
E
GMVM960603BX
17½”
28¾"
40¾"
17½”
16"
13⅛"
12⅛"
13⅝"
GMVM960805CX
21"
28¾"
40¾"
21"
19½”
16⅛"
16"
17½”
GMVM961005DX
24½”
28¾"
40¾"
24½”
23"
20⅝"
19⅜"
20⅞"
GMVM961155DX
24½”
28¾"
40¾"
24½”
23"
20⅝"
19⅜"
20⅞"
Notes:
•  Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” 
in diameter, depending upon furnace input, number of elbows, length of run and installation  
(1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
•  Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.
•  Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.
•  Installer must supply following gas line fittings, according to which entrance is used: 
Left—Two 90º elbows, one close nipple, straight pipe 
Right—Straight pipe to reach gas valve
•  For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.