Ordering Data: Please specify gas type (natural or propane) when ordering. 
MODEL NUMBER
WD-27-SS-OD
DRAWER SPACE
1.6 CUBIC FEET
REMOVABLE SHELF/SERVING TRAY
TYPE 304 STAINLESS STEEL
Gas Requirements:
Natural
• 1/2" NPT male with a 3/8" flare adapter
• Operational Pressure:  4" W.C.
• Supply Pressure: 6” to 9” W.C.
Power Requirements:
• 120V 60Hz
• 3 wire
• 15 amp circuit
MODEL NUMBER
BGB131
BGB131-BI
BGB132
BGB132-BI
30” CART MOUNT
BUILT-IN
SIDE BURNER(S) 
1 @ 17,000 Btu/hr
1 @ 17,000 Btu/hr
2 @ 17,000 Btu/hr
2 @ 17,000 Btu/hr
SHIPPING WEIGHT 
(LBS)
35.4
35.8
60.6
64.0
SHIPPING DIMENSIONS 
(HEIGHT X WIDTH X DEPTH)
13.5 x 14.5 x 19
13.5 x 14.5 x 19
16 x 18 x 30
16 x 18 x 30
B
B
B
Note: the deck is
not required
8
8
Built-in Side Burner Dimensions
30” Cart Mount Side Burner Dimensions
Professional Side Burner
Island Preparation
NOTE: Cart Mount Side Burners are not designed for built-in applications.
Warming Drawer Dimensions
Warming Drawer Island Preparation
MODEL
A
B
BGB131-BI
12”
6” min.
BGB132-BI 
22-3/8”
6” min.
POWER
CORD
A 120 Volt AC GFI
outlet should  be
located below the
Warming Drawer
2 x 4’s or similar
support
min. cabinet depth
1-1/2” min. to
bottom of 
countertop
Propane
• 1/2" NPT male with a 3/8" flare adapter
• Operational Pressure:  10" W.C.
• Supply Pressure: 11” to 14” W.C.
BGB132-BI
BGB131-BI
BGB131
BGB132
BGB131 Single Side Burner
BGB132 Double Side Burner
BGB131-BI Single Side Burner
BGB132-BI Double Side Burner