Cabinet Series Dehumidifying Dryer 
 
45 
Option Type 
RE232C 
RS-485 
Event Input 
Transfer Output 
Board Number 
E53-CK01 
E53-CK03 
E53-CKB 
E53-CKF 
 
Mode Parameter 
Setting 
range 
Default 
Factory 
setting 
Option  Eu-A Multi-SP Function  
0/1 
Default 
Option  Eu-1 Event Input Assign 1 
STOP/MAN 
STOP 
Default 
Option  SbCE Communication Stop Bit 
½ BITS 
Default 
Option  Len Comm. Data Length  
7/8 BITS 
Default 
Option  PrEY Commication Parity 
None/Even/Odd 
Even 
Default 
Option  6PS Comm. Baud Rate 
1.2/2.4/4.8/9.6/19.2 
9.6 kbps 
Default 
Option  U-n6 Comm. Unit No. 
0 to 99 
Default 
Option  Er-E Transfer Output Type 
SP/SP-M/PV/O/C-O 
SP 
Default 
Option  Er-H Xfer Output Upper Limit 
Default 
Option  Er-L Xfer Output Lower Limit 
Default 
 
Restoring Factory Defaults on the Dew Point Controller 
 
1.  Make sure jumper setting for input type is set for Current Input (I), right jumper. 
2.  Return controller to housing. 
3.  Press the Display button for one (1) second to enter Menu Display. 
4.  Press the Arrow Up button to switch between menus. 
5.  To switch parameters within a menu, press Up Arrow button. 
Figure 9 
Setting List for Dew Point Controller, Part No. A0548567 
Mode Parameter 
Setting 
range 
Default 
Factory 
setting 
Protect  SECr Security  
0 to 6 
Protect  YEYP A/M Key Protect 
ON/OFF 
OFF 
ON 
Manual  Manual MV 
-5.0 to 105.0 % 
0.0 
Default 
Level 0  SP Set Point 
SP lower limit to upper limit EU
Default 
Level 0  r-S Run/Stop 
Run/Stop 
Run 
Default 
Level 1  AL-1 Alarm Value 1 
-1999 to 9999 EU 
-10.0
°F/-23°C
Level 1  AL-2 Alarm Value 2 
-1999 to 9999 EU 
-10.0
°F/-23°C
Level 1  C-db Dead Band 
-19.99 to 99.99%FS 
0.00 
Default 
Level 1  HYS Hysteresis (Heat) 
0.01 to 99.99% FS 
0.10 
Default 
Level 1  CHYS Hysteresis (Cool) 
0.01 to 99.99 FS 
0.10 
Default 
Level 2  SPrU Sp Ramp Time Unit  
M(Minutes)/H(Hours) 
Default 
Level 2  SPrt Sp Ramp Set Value 
0 to 9999 EU 
Default 
Level 2  CnF Input Digital Filter 
0 to 9999 SEC 
Default 
Level 2  ALH1 Alarm 1 Hysteresis 
0.01 to 99.99% 
0.02 
Default 
Level 2  ALH2 Alarm 2 Hysteresis 
0.01 to 99.99% 
0.02 
Default 
Level 2  Cn5H input shift upper limit 
-199.9 to 999.9
°C 
0.0 Default