Sterling SDA 1000-5100 Benutzerhandbuch

Seite von 61
Large Dehumidifying Dryers  
Maintenance 
47 
High 
Temperature 
Gasket
Double Wall 
Stainless Steel 
Heater 
Housing
Heater Elements
Heater Element 
Mounting Plate
Stainless Steel 
Heater Housing 
Cover
High 
Temperature 
Gasket
Heater Assembly 
Gude Bars
1.  Remove the bolts securing the process heater access cover. 
2.  Sketch the heater wiring configuration so the heaters may be re-wired properly. 
Heaters are mounted on a common plate of three or six for easy maintenance. 
3.  Remove the jumper bars and wires for the heater plate assembly(ies) being removed 
or replaced. 
4.  Remove the bolts securing the heater plate assembly and slide out the assembly. 
Avoid damaging the gaskets. 
5.  Remove individual heaters for replacement by removing the large brass nuts and 
washers. 
6.  Re-install the heaters and heater plate assemblies in reverse order, replacing gaskets 
if necessary.  
 
Caution! 
Heater loops should not touch each other. "Hot spots" will lead to 
premature heater failure. 
7.   Re-install the jumper wires and bars according to the sketch made earlier. 
8.    Re-secure the process heater access cover. 
Figure 19: Process Heater Box Assembly 
 
 
 
 
 
 
 
 
 
 
 
Replacing the Regeneration Heater (Electric Dryers) 
The regeneration heaters are wired in the delta formation, mounted in the core of the descant 
tanks. 
DANGER! 
Disconnect and lock out power before heater replacement. 
Heater Element
Heater Element
Bulkhead Fitting
Heater Element
Mounting Hex Nut
Hex Nut For
Securing the Heater 
Wire
Washer
Heater Wire with 
Crimped on Closed 
Loop Connector
High Temperature 
Washer / Gasket
Heater Mounting 
Plate
Heater Assembly 
Guide Bar
Heater Elements
Heater Element 
Mounting Plate
High 
Temperature 
Gasket
Double Wall 
Stainless Steel 
Heater 
Housing
Stainless Steel 
Heater Housing 
Cover
Heater Assembly 
Gude Bars