Intended Application for Ultra-Aire XT150H 
For the ideal installation, draw air from the central part of the home 
and return it to isolated areas of the home like the bedrooms, den, 
utility room, or family room. The ductwork of the existing heating 
system can be used to supply air to the home. 
2. Specifications
Model:  
 Ultra-Aire XT150H  
Indoor Air Quality System 
Electrical:  
 110-120 VAC, 6.9 Amps, 60 Hz, 
grounded 
Water Removal Capacity:   150 pints/day @ 80°F, 60% RH 
Operating Temp. Range:  
56°F min., 100°F max. 
Air Flow:  
415 CFM @ 0.0" WG  
 
365 @ 0.4" WG 
Refrigerant Charge:  
2 lb., R-410.A
Duct connections:  
Round 10" & 6" inlets, 10" outlet 
(ovaled)
Filter Size:  
 2" X 16" X 16" 
Size (w/o duct collars):  
37" wide X 22" high X 20 5/8" deep
Unit Weight:  
134 lbs.
3. Installation
3.1 Location
The Ultra-Aire XT150H can be installed in a variety of locations 
to meet the owner's needs as listed below. In all cases keep the 
following cautions in mind:
•  It is designed to be installed INDOORS IN A SPACE THAT IS 
PROTECTED FROM RAIN AND FLOODING.
•  Install the unit with space to access the back and side panels for 
maintenance and service and also to allow easy access to the filter 
cover panel. DO NOT INSTALL UNIT WITH THE FRONT PANEL OR 
FILTER COVER PANEL INACCESSIBLE.
•  Avoid discharging the air directly at people, or over the water in 
pool areas.
•  If used near a pool or spa, be certain there is NO chance the unit 
could fall into the water or be splashed and that it is plugged into a 
GROUND FAULT INTERRUPTER. 
• DO NOT use the Ultra-Aire XT150H as a bench or table. 
•  DO NOT place the Ultra-Aire XT150H directly on structural 
members. Provide vibration isolation in order to minimize 
operational vibration and/or noise.
•  A drain pan MUST be placed under the unit if installed above a 
living area or above an area where water leakage could cause 
damage. 
Place the Ultra-Aire XT150H on supports that raise the base of 
the unit above the top of the flanges on the drain pan beneath it. 
Raising the Ultra-Aire XT150H will help the unit drain with gravity 
flow. Do not place the Ultra-Aire XT150H directly on structural 
building members without vibration absorbers or unwanted noise 
may result. 
The Ultra-Aire XT150H may be suspended with steel hanger straps 
(plumbers tape) or a suitable alternative from structural members, 
unit must be supported from underneath. Don't hang from sides 
or ends. Remember to place a drain pan under the unit if it is 
suspended above a finished area or above an area where water 
leakage could cause damage. 
The Ultra-Aire XT150H should be located near the existing air 
handling system to minimize the required ductwork for connecting 
the Ultra-Aire XT150H to the existing air handling system. The 
controls for the Ultra-Aire XT150H are remote from the unit and 
must be located in the space that is to be conditioned. The controls 
are low voltage (24 volt) and should be connected to the Ultra-Aire 
XT150H with low voltage thermostat cable. 
If fresh air ventilation is desired, thought should be given to the 
location for the fresh air ducting. A 6" round insulated duct will 
have to be installed on the Ultra-Aire XT150H and run to the outside 
of the structure to bring in fresh air. Use an 8" insulated round duct 
for lengths of more than 50 feet or if more than 100 CFM is needed. 
Consult local codes for necessary distances from exhaust ports 
when installing fresh air return. 
3.2 Electrical Requirements 
WARNING: 
DO NOT ALLOW THE YELLOW LEAD FROM THE 
ULTRA-AIRE TO CONTACT THE RED LEAD OR WHITE LEAD FROM 
THE ULTRA-AIRE OR DAMAGE TO THE TRANSFORMER WILL 
RESULT.
The Ultra-Aire XT150H plugs into a common grounded outlet. It 
draws around 6.9 Amps under normal operating conditions. If used 
in a wet area (pool, spa room, or basement prone to flooding), a 
ground fault interrupter protected circuit is required. 
Install the remote control panel in a central area of the structure 
where it will sense the relative humidity of the structure accurately. 
Do not install the control panel where it may not accurately sense 
the relative humidity such as near HVAC supply registers, near 
exterior doors, or near a pool or spa. The installer must supply the 
wiring between the Ultra-Aire XT150H and the control panel. Be 
sure to safely route the control wiring to prevent damage during 
installation. Be careful not to cross the wires when connecting the 
Ultra-Aire XT150H and the remote control panel or damage to the 
transformer may result. 
FOR HVAC INSTALLER ONLY
4
Ultra-Aire XT150H Installer’s & Owner’s Manual