Honeywell 69-2035EFS-05 Benutzerhandbuch

Seite von 36
TrueSTEAM Direct-Injection Humidifier
 
 
69-2035EFS—05
2.  Turn the manual shut-
off valve at the bottom 
of the tank to the 
“Unlock” position.
M24777
M24778
M24779
4. Firmly grip the tank 
bottom. Push down the 
cover's safety button and 
pull the latch forward to 
release the tank.
Note: Latch does not come 
off humidifier with tank.
3. Grip the white water 
valve arm and slide it 
back within the bracket 
to disengage from the 
tank.
Cleaning and maintenance
 5. Use tap water to flush loose minerals 
from the tank. Sediment screen at 
tank's bottom is removable. For a more 
thorough cleaning, soak tank in warm, 
soapy water, then rinse clean. Tank is 
also dishwasher-safe.
M24857
6.  Carefully rub minerals off of the heating 
element and reservoir walls. Scouring 
pads suitable for non-stick pots or pans 
are suitable for cleaning the TrueSTEAM 
reservoir walls and components within the 
tank.
M24856
 Sediment screen
Once clean, reattach tank by securing the latch. Engage the water valve to the cam shaft, and 
“Lock” the shut-off valve. The “Press Reset” light will blink at start-up. Push the RESET button 
to ready the humidifier.