Therma-Stor Products Group 135H Benutzerhandbuch

Seite von 12
2
Ultra-Aire 135H Air Purifying Dehumidifier Owners Manual
Table of Contents
Introduction
1
Features & Benefits
1
1. Intended Application
2
2. Registrations
2
3. Specifications
2
4. Operation
2
4.1 Humidity/Fan Control Panel 
WITHOUT Fresh Air Ventilation or Damper
3
4.1A Humidity/Fan Control Panel WITH Fresh 
Air Ventilation and WITHOUT Damper
3
4.1B Humidity/Fan Control Panel WITH
Fresh Air Ventilation AND Damper
3
4.1C Ventilation Timer and Humidity Control 
WITH Fresh Air AND Motorized Damper
3
4.1D DEH 2000 Digital Controller WITH
Fresh Air AND Damper
3
4.1E DEH 2000 Digital COntroller 
WITHOUT Fresh Air
4.2 Humidity Control Adjustment
3
4.3 Fan/Filter Switch
3
4.4 Ventilation Timer
3
4.5 Setting the Time
4
4.6 Ventilation Schedule
4
4.7 Automatic or Manual Mode
4
4.8 Low Pressure Control
4
5. DEH 2000 Digital Control
4
5.1 Specifications
4
5.2 Operation
4
5.2A Display
4
5.2B Setting
5
5.2C On/Off Setting
5
5.2D Setting Clock Time
5
5.2E Setting Relative Humidity Setpoint
5
5.2F Fan Setting and Operation
6
5.2G Fan On Fan Off Fan Program
6
5.2H Damper Operation and Setting
6
5.2I Intermittent/Programmed Ventilation 6
5.2J Programming Notes
7
5.2K Stop Start
7
6. Maintenance
7
6.1 Standard Air Filter
7
6.2 High Efficiency Air Filter
7
6.3 Fresh Air Return
7
7. Service
7
7.1 Technical description
7
7.2 Troubleshooting
8
7.3 Refrigerant Charging
9
7.4 Impeller Fan Replacement
9
7.5 Compressor/Capacitor Replacement
9
7.6 Replacing Compressor - Nonburn Out
9
7.7 Electric Ventilation Damper
9
7.8 Condensate Pump Kit
9
8. Warranty
10
9. Optional Parts List
11
1 Intended Application for Ultra-Aire 135H
For the ideal installation, draw air from the central part of the
home and return it to isolated areas of the home like the bed-
rooms, den, utility room, or family room. The ductwork of the
existing heating system can be used to supply air to the home. 
2 Registrations
The Ultra-Aire 135H (P/N 4025080) conforms to 
UL STD 1995. Certified to CAN/CSA STD C22.2 No. 236.
3 Specifications
Model: 
UA-135H Air Purifying Dehumidifier
Electrical: 
110-120 VAC, 12 Amps, 60 Hz, grounded
Capacity: 
135 pints/day @ 80°F, 60% RH
Operating Temp.: 55°F min., 100°F max.
Air Flow: 
355 CFM without external ducting
335 CFM @ .20 IWG external static
315 CFM @ .40 IWG external static
Refrigerant Charge:  
1 lb., 12 oz. R22
Duct Connections:
Round 10" inlet, 10" outlet
Filter Size: 
Pleated cloth: 2" X 20" X 24"
High Efficiency: 4" X 20" X 24"
Unit Size (w/o duct collars):  
31"L x 21"W x 18.65"H
Shipping Size: 
37”L x 25”W x 28.5”H
Unit Weight: 
100 lb.   
Shipping Weight:
138 lb.
4 Operation
The Ultra-Aire UA-135H Air Purifying Dehumidifier performs 
three functions in one compact enclosure; High-Capacity
Dehumidification, Fresh Air Ventilation, and Filtration. The 
UA-135H can be equipped with various accessories to
enhance its operation. A remote control panel must be 
used with the UA-135H. Your unit has one of three remote
control panels. To determine how each control operates 
the UA-135H it must first be determined which control is
being used and whether or not the 135H is ducted for fresh
air ventilation. Refer to Section 7 to identify which control 
you have installed. Inspect ducting or contact your installer 
to determine if your UA-135H is ducted for outside air.
Humidity/Fan Control Panel (P/N 4024155)
4.1 
Humidity/Fan Control Panel WITHOUT Fresh Air
Ventilation or Damper
4.1A 
Humidity/Fan Control Panel WITH Fresh Air
Ventilation and WITHOUT Damper
4.1B
Humidity/Fan Control Panel WITH Fresh Air
Ventilation AND Damper
Ventilation Timer/Humidity Control Panel (P/N 4024125)
4.1C
Ventilation Timer and Humidity Control WITH Fresh
Air AND Motorized Damper
DEH 2000 Digital Control (P/N 4024539)
4.2 
DEH 2000 Digital Controller WITH Fresh Air 
AND Damper
4.2A 
DEH 2000 Digital Controller WITHOUT Fresh Air