Intrepid II Woodburning Stove
2000966
A Damper Directs Air Flow                   
Within the Stove
The damper handle opens and closes the damper to 
direct air flow within the stove, and is next to, and to the 
right of, the primary air control lever on the right side of 
the stove. (Fig. 34)
When the handle points to the floor, the damper is 
open, letting smoke pass directly into the chimney. The 
damper must be open when starting or reviving a fire, 
and whenever the griddle or doors are opened.
When the handle points to the front, the damper is 
closed. Smoke from the fire travels through the catalytic 
combustion system where it can burn further for greater 
efficiency, before passing up the chimney. 
The damper has no intermediate positions. Figure 28 
shows the handle’s open and closed positions.
When closing the damper, push firmly and snap it 
into the locked position to ensure that the stove 
remains in the catalytic mode.
Andirons
Your stove has andirons to keep logs away from the 
glass panels. The andirons are important to maintain 
clear fireviewing and should be removed only while 
reloading through the front doors.  
Wear heavy stove gloves when removing the andirons, 
and place them on a noncombustible surface until you 
replace them in the stove. Most stove owners will prefer 
the convenience of top loading through the griddle, and 
will leave the andirons in place permanently.
ST519
Intrepid II
damper
11/20/00   djt
Open
(Updraft Mode)
Closed
(Catalytic Mode)
ST519
Fig. 34  The damper is either open or closed. There are no 
intermediate positions.
Side View
ST520
Intrepid
andirons
11/20/00   djt
ST520
Fig. 35  Remove the andirons for front loading.
Two Ways to Add Fuel
The Intrepid II’s griddle lifts for convenient top-loading 
of logs, and is the easiest way of regularly adding fuel. 
However, the front doors open as well for adding an oc-
casional log to a fire. (Fig. 36) 
You can open (or even remove) the front doors and 
place the optional Intrepid II spark screen in the front 
opening for open-fire viewing.
INTREPID  II
ST521
Intrepid
loading
11/00
ST521
Fig. 36  Top loading is the best way to add fuel during regular 
use. Front loading is useful for kindling a fire.
Glass Door Panels
The glass panels in the doors have a heat-reflective 
coating on the outside surface. Heat reflected back to 
the inside of the glass helps keep the inner surface at 
a higher temperature than the outside. In combination 
with pre-heated primary combustion air ‘washing’ over 
the inside of the glass, this helps provide clear fire-
viewing at most operating levels.