Dutchwest Direct Vent / Natural Vent Gas Heater
30001935 
General Information
The Dutchwest Direct Vent/Natural Vent Room Heater, 
Model  Nos. 3070, 3071, 3072 and 3073, is a vented gas 
appliance listed to the ANSI standard Z21.88b-2001  and 
CSA-2.33b-2001 for Vented Room Heaters, and  CSA 2.17-
M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Dutchwest Direct Vent/Natural 
Vent Room Heater must conform with local codes, or in the 
absence of local codes, with National Fuel Gas Code, ANSI 
Z223.1/NFPA 54 — latest edition and CSA B-149.1  Instal-
lation Code. (EXCEPTION:  Do not derate this appliance 
for altitude.  Maintain the manifold pressure at 3.5”  w.c. for 
Natural Gas and 10.0” w.c. for LP gas at maximum input.) 
This appliance is only for use with the type of gas indicat-
ed on the rating plate. This appliance is not convertible for 
use with other gases unless a certified kit is used. 
Installation and replacement of gas piping, gas utiliza-
tion equipment or accessories, and repair and servicing 
of equipment shall be performed only by a qualified 
agency.  The term “qualified agency” means any individ-
ual, firm, corporation, or company that either in person 
or through a representative is engaged in and is respon-
sible for  (a) installation or replacement of gas piping, 
or (b), the connection, installation, repair, or servicing 
of equipment, who is experienced in such work, familiar 
with all precautions required, and has complied with all 
the requirements of the authority having jurisdiction.
The Dutchwest Direct Vent/Natural Vent Room Heater 
should be inspected before use and at least annually by 
a qualified service agency. It is imperative that control 
compartments, burners, and circulating air passage-
ways of the appliance be kept clean.
 
The Dutchwest Direct Vent/Natural Vent Room Heater and 
its individual shut-off valve must be disconnected from the 
gas supply piping during any pressure testing of that system 
at test pressures in excess of 1/2 psig (3.5 kPa).
The Dutchwest Direct Vent/Natural Vent Room Heater 
must be isolated from the gas supply piping system by clos-
ing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures 
equal to or less than 1/2 psig.
‘Direct Vent’ describes a sealed combustion system in 
which incoming outside air for combustion and outgoing 
exhaust enter and exit through two separate concentric 
passages within the same sealed vent system. The system 
does not use room air to support combustion. The Direct 
Vent system permits the gas appliance to be vented directly 
to the outside atmosphere through the side of the house or 
vertically through the roof. Conventional venting systems 
(Natural Vent) take air from the room for combustion and 
vent the exhaust vertically through the roof to the atmo-
sphere.
This appliance is approved for bedroom installations in the 
U.S. and Canada.
This appliance may be installed in an aftermarket* manu-
factured (mobile) home, where not prohibited by state or 
local codes. 
WARNING: Operation of this heater when not con-
nected to a properly installed and maintained venting 
system can result in carbon monoxide (CO) poisoning 
and possible death.
The Dutchwest Direct Vent/Natural Vent Room Heater, 
when installed, must be electrically grounded in accordance 
with local codes or, in the absence of local codes, with the 
National Electrical Code ANSI/NFPA 70, (latest edition), or of 
the current Canadian Electrical Code C22.1.
Due to high temperatures this appliance should be 
located out of traffic and away from furniture and drap-
eries.
WARNING:  This appliance is hot while in operation.  
Keep children, clothing, and furniture away.  Contact 
may cause burns or ignition of combustible materials.
Children and adults should be alerted to the hazards 
of high surface temperatures and should stay away to 
avoid burns or clothing ignition. Young children should 
be carefully supervised when they are in the same room 
as the appliance.
Clothing or other flammable materials should not be 
placed on or near the appliance. 
Any safety screen, glass or guard removed for servic-
ing an appliance must be replaced prior to operating the 
appliance.
The appliance area must be kept clear and free from 
combustible materials, gasoline, and other flammable 
vapors and liquids.
The flow of combustion and ventilation air must not 
be obstructed. The installation must include adequate 
accessibility and clearance for servicing and proper 
operation.
WARNING:  Do not operate the Room Heater with the 
glass panel removed, cracked or broken. Replacement 
of the panel should be done by a licensed or qualified 
service person.
Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control which has been 
under water.
Do not burn wood, trash or any other material for 
which this appliance was not designed. This appliance 
is designed to burn either natural gas or propane only.
This gas appliance must not be connected to a chim-
ney flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause improper 
and dangerous operation.
Verify proper operation after servicing.
Proposition 65 Warning:
 Fuels used in gas, woodburn-
ing or oil fired appliances, and the products of combustion of 
such fuels, contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects and other reproductive 
harm.
California Health & Safety Code Sec. 25249.6