Jotul GZ550s Benutzerhandbuch

Seite von 32
18
Wall Thermostat Installation
Use Jøtul Thermostat #129706 or a 750 millivolt DC
two-wire circuit thermostat
 to automatically control
your fireplace operation. The thermostat should be
placed in the same room as the heater, typically 5’
off the floor.  Avoid drafty areas or any area that
may affect the accuracy of the thermostat.
The thermostat should be connected to the
Acadia using a minimum of 16 gauge wire with  a
maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the
two lower terminals on the terminal block located
to the right of the ON/OFF/T’STAT switch. Do not
overtighten the connections.  IT IS NOT NECESSARY
TO DISCONNECT ANY OTHER WIRES. See Figure 34.
At the thermostat, the two wires should be
connected to the two connections screw on the
thermostat base plate per the manufacturer’s
instructions.
For thermostatic function, place the ON/OFF/T-
STAT switch in the T-STAT position and the pilot
flame must be lit.
Figure 33.  ZG550 DV Acadia Blower Wiring Diagram
Remote Control
The optional Jøtul Remote Control  can be installed
on the Acadia gas fireplace.  Using the wire sup-
plied with the remote, connect the remote directly
to the gas control valve.
 Connect one receiver lead to the terminal
labelled TH.  Connect the other receiver lead to the
terminal labeled TH/TP.  DO NOT DISCONNECT ANY
OTHER WIRES FROM THE VALVE, AND DO NOT OVER
TIGHTEN THE TERMINAL SCREWS.
Place the receiver unit under the control valve
on the floor of the fireplace cabinet.
CAUTION:
LABEL ALL WIRES PRIOR TO DIS-
CONNECTION WHEN SERVICING
THE CONTROLS.  WIRING ERRORS
CAN CAUSE IMPROPER AND DAN-
GEROUS OPERATION.  ALWAYS
VERIFY PROPER OPERATION AFTER
SERVICING THE APPLIANCE.
ATTENTION:
AU MOMENT DE L’ENTRETIENDES
COMMANDES, ETIQUETEZ TOUS LES
FILS AVANT LE DEBRANCHEMENT.
DES ERREURS DE CABLAGE
PEUVENT ENTRAIUN
FONCTIONNEMENT INADEQUAT ET
DAGEREUX.
Figure 34. ZG550  Acadia Wiring Diagram
LO
HI
SNAPSTAT
WHITE
BLACK
RED
BLACK
BLACK
RED
WHITE
GREEN
BLOWER
POWER
SUPPLY
CONTROL
SWITCH
TERMINAL
BLOCK
VALVE
THERMOPILE
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
TH
TP
TH
TP
ROCKER
SWITCH
ON
OFF
STAT