Monessen Hearth 36CDVXTRN Benutzerhandbuch

Seite von 44
15
CDVX Series Direct Vent Gas Fireplace
20012253
FP1005
Side View Vent Termination
1/25/00   djt
22”
(559 mm)
CL
Finished 
Wall
Secure with Screw
Vent Termination
Firestop
FP1005a
Fig. 19  Side view of final unit location.
Rear Wall Vent Installations - 
45° Flex Vent Pipe
Using Kit 7TCD45KT
NOTE: The corner placement dimensions on Page 
5, Figure 1 of the manual must be adhered to! 
Figures 20 & 21 show general installations. Refer to 
instructions below for a detailed description of instal-
lation.
1.  Determine where the termination is to be in-
stalled. Locate the center of the hole 29Z\x” 
(749 mm) off the floor. (Fig. 20)
NOTE: The location of the termination hole must be 
adhered to!
2.  Install the firestop as shown on Page 14.
3.  Remove the flex vent and extend the flex vent out 
to its longest length.
4.  Bend the tab on the back of the fireplace up. (Fig. 
18)
5.  Insert the collar on the flex vent that has the twist 
lock embosses on it onto the collar of the fire-
FP1473
corner flex install
4/04  djt
CL
to Floor
2956O”
(749 mm)
Termination
Flex Section
Appliance 
Collars
FP1473
Fig. 20  Grasp the vent pipe close to the collar and bend to 
45° angle. Do not exceed 45°.
place. Twist the collar to “lock it” onto the fireplace. 
Run a screw through the tab and into the collar to 
secure the collar onto the fireplace.
6.  Bend the flex pipe up 90° as close to the fireplace 
as possible. (Fig. 21)
7.  Slide the fireplace partially into the corner and, 
while holding the vertical portion of the flex vent 
pipe, grab the exposed end collar and bend it down 
to the height of the opening in the wall.
8.  While pushing the unit in place, slide the collar 
through the firestop. NOTE: It may be necessary 
to trim some material off of the collar. The collar is 
made long to accommodate brick finished houses. 
(Fig. 23)
9.  Secure the collar in place by running a screw 
through the tab in the firestop and through the col-
lar.
10. Slide the termination into the collar and secure 
with the 4 screws provided. (Fig. 23)