CDVX Series Direct Vent Gas Fireplace
20012253
FP1242
Fig. 51  Through the wall.
FP1243
Fig. 52  Apply high temperature sealant to collars or termina-
tions.
Below Grade Installations
When it is not possible to meet the required vent ter-
minal clearances of 12” (305 mm) above grade level a 
snorkel vent kit is recommended.  It allows installation 
depth of down to 7” (178 mm) below grade level.  The 
7” is measured from the center of the horizontal vent 
pipe as it penetrates through the wall.
If venting system is installed below 
ground, we recommend a window well with 
adequate and proper drainage.
Ensure sidewall venting clearances are observed.
If installing a snorkel a minimum 24” (610 mm) vertical 
rise is necessary. The maximum horizontal run with 
the 24” (610 mm) vertical pipe is 36” (914 mm). This 
measurement is taken from the collar of the fireplace (or 
transition elbow) to the face of the exterior wall. Refer to 
the Sidewall Vent Graph for extended horizontal run if 
the vertical rise exceeds 24” (610 mm).
1.  Establish vent hole through the wall. (Page 14, Fig. 
17)
2.  Remove soil to a depth of approximately 16” (406 mm) 
below base of snorkel. Install drain pipe. Install win-
dow well (not supplied). Refill hole with 12” (305 mm) 
of coarse gravel leaving a clearance of approximately 
4” (102 mm) below snorkel. (Fig. 53)
3.  Install vent system.  
4.  Ensure a watertight seal is made around the vent pipe 
coming through the wall.
5.  Apply high temperature sealant caulking around the 4” 
and 7 “ snorkel collars.
6.  Slide the snorkel into the vent pipes and secure to the 
wall.
7.  Level the soil to maintain a 4” (102 mm) clearance 
below snorkel. (Fig. 53) 
Do not back fill around snorkel. A clearance 
of at least 4” (102 mm) must be maintained 
between snorkel and the soil.
If the foundation is recessed, use recess brackets (not 
supplied) for securing lower portion of the snorkel.  
Fasten brackets to wall first, then secure to snorkel 
with self drilling #8 x 1/2 sheet metal screws. It will be 
necessary to extend vent pipes out as far as protruding 
wall face. (Fig. 54)