DVB4136 Direct Vent Gas Fireplace
20012322
Clearance to Combustibles
Top of unit to ceiling ................................. 36” (914 mm)
Front of unit to combustibles ................... 36” (914 mm)
Appliance
 
Top of standoff  ....................................... 0” (0 mm)
 
Bottom ..................................................... 0” (0 mm)
 
Side ......................................................... 0” (0 mm)
 
Back ........................................................ 0” (0 mm)
Venting
Concentric sections of DV Vent ................... 1” (25 mm)
Nonconcentric sections of DV Vent
 
Sides and bottom .................................. 1” (25 mm)
 
Top ........................................................ 2” (51 mm)
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For the correct mounting height and widths, refer to 
Figures 4a, 4b and the Mantel Chart below.
The distances and reference points are not affected by 
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance. When using 
paint or lacquer, it must be heat resistant to prevent 
discoloration. 
CFM146
Bottom of Door Trim
Mantel Chart
 
 
Mantel Shelf 
 
Mantel from Top
  Ref.  or Breast Plate 
Ref.  of Comb. Chamber 
 
 
Depth
 
10”   (254 mm) 
19”   (483 mm)
  W 
8”   (203 mm) 
17”   (432 mm)
 
6”   (152 mm) 
15”   (381 mm)
 
4”   (101 mm) 
13”   (330 mm)
 
2”   (51 mm) 
11”   (279 mm)
Fig. 4a  Combustible mantel minimum installation.
Hearth
A hearth is not mandatory, but is recommended for 
aesthetic purposes. We recommend a noncombustible 
hearth which projects out 12” (305 mm) or more from 
the front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a non-in-
sulated exterior wall or chase, it is manda-
tory that the outer walls be insulated to 
conform to applicable insulation codes.
Y
E
A
B
C
D
F
Y
B
X
LU584-1
Locating unit
2/4/99   djt
Locating Your Fireplace
LU584-1
A) Flat on wall  
B) Cross corner 
C)  **Island
D) *Room divider  E) *Flat on wall corner 
F)   Chase installation
Y) 0” minimum (Check minimum if mantel leg is used)
NOTE (Fig. 3):  
** Island (C) and Room Divider (D) installation is possible as long as 
the horizontal portion of the vent system (X) does not exceed 20’ (6 
m).  See details in Venting Section.
*  When you install your fireplace in(D) Room divider or (E) Flat 
on wall corner positions (Y), a minimum of 6“ (152 mm) clearance 
must be maintained from the perpendicular wall and the front of the 
fireplace.
Fig. 3  Locating gas fireplace.
Framing and Finishing
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance: Choose the location. (Fig. 5)
1.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 1/2” 
drywall while flange “B“ is for 5/8” drywall.
2.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in 
place.
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01   sta
Louvre Assembly 
top
Top of Combustion 
Chamber
Standoff
Noncombstible 
Material
3/4” (19 mm) Scribe moulding 