     SECTION  II 
RESIDENTIAL INSTALLATION OF GAS LOGS 
FIREPLACE PREPARATION 
The fireplace needs to be prepared before installing the gas logs. 
 
  A. Turn off the gas supply to the fireplace. 
  B. Any outside air ducts on the fireplace shall be permanently closed at the time of the  
       appliance installation. 
 
  “WARNING: BEFORE INSTALLING IN A SOLID FUEL BURNING FIREPLACE, 
     THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT,              
     CREOSOTE, ASHES AND LOOSE PAINT BY A QUALIFIED CHIMNEY 
     CLEANER”. 
    “WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO 
       THE  FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME 
        PATTERN”. 
  LOCATION 
Centrally locate the gas logs in the fireplace. Place them deep enough into the fireplace to  
accomplish  adequate draft (if use as a vented gas log set is planned). Ensure that front of the 
logs sit inside the edge of the fireplace.  
                                                                                
 
NOTE: IF THE EXISTING FIREPLACE IE EQUIPPED WITH A SCREEN IT MUST 
BE IN PLACE WHEN THE APPLIANCE IS OPERATING . THE SCREEN SHALL 
HAVE ADEQUATE OPENING (S) FOR INTRODUCTION OF COMBUSTION AND 
VENTILATION  AIR. 
 
NOTE: MAINTAIN PROPER CLEARANCE FOR PURPOSE OF SERVICING, 
PROPER INSTALLATION, AND OPERATION. 
 
Mantel minimum clearances 
for a listed Zero Clearance 
Firebox or a Masonry Fire- 
place. 
*WARNING: Canopy 
model MAPSFPC must be 
used  at all times unless a 
10-inch mantel is installed 
at 36-inches above the fire-
place opening. (Can be ob-
tained from your local 
dealer or purchased from 
the factory.)
 
ANGLE MANTEL 
FLAT MANTEL 
FIGURE  1 
Top of firebox opening 
2.5” 
14”
18” 
20” 
10” TO 12” Out From Wall 
6” To 10” Out From Wall 
0” To 6” Out From Wall 
MAX. OF 2 1/2” 
Top of firebox 
opening 
10” 
12” 
14” 
8” TO 10” OUT FROM WALL 
6” TO 8” OUT FROM WALL 
0” TO 6” OUT FROM WALL 
2.5” 
16” 
10” TO 12” OUT FROM WALL 
4