Regency P42-NG3 Benutzerhandbuch

Seite von 44
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace
24
Burner tray without
  front logs in place
All 3 logs in place
PROPANE
LOG SET INSTALLATION
NATURAL
GAS
IMPORTANT
For Propane Units - only place rockwool on the
rear burner tray behind the burner tube.
WARNING: Dangerous operating
conditions may occur if these logs
are not positioned in their correct
certified locations. Read the fol-
lowing instructions carefully and
refer to the attached diagram.
1) Remove the logs from the box and carefully
unwrap them. The logs are fragile, handle
with care. Do not force into position.
2) Place the rear log on the rear log support in
the back of the unit with the flat side of the
log facing the back of the unit. Carefully
push the log down onto the pins.
3) Sprinkle the vermiculite on the sides and
front of the fireplace bottom being careful
not to get any into the air shutter or the
burner ports (burner ports are the little
holes in the top of the burner). The vermicu-
lite is used to cover the sheet metal and
hardware on the firebox floor and burner
assembly.
4) Pull off ember size pieces of rockwool and
gently place them around the whole burn-
er. Do not compress the rockwool, leave it
loose for the most realistic looking embers.
Refer to the diagrams below for correct
placement of rockwool on the Natural Gas
and Propane units.
5) Place the front logs in the unit, aligning the
holes on the underside of the logs with the
log support pins in the front of the unit.
Carefully push the logs down onto the pins.
(Hint: Install the front right side first.)
6) Place a few embers under the front logs
and a few under the front part of the burner
assembly to make it look like fallen embers.
7) Test for pilot ignition.
8) Install the door and louvers.
INSTALLATION