Regency
®
 E21-3 Gas Fireplace Insert
Note:  Do not operate unit if fl ue connector is not 
fastened in original position.
FLUE CONNECTOR INSTALLATION 
1)  Remove the screw holding the fl ue connector 
plate to the appliance.
2)  Slide the plate out and attach to the fl ue liner 
inside the fi replace to the fl ue collar with three 
sheet metal screws.
3)  Place the appliance on the hearth. Push 
the appliance into the fi replace and at the 
same time slide the plate back onto the ap-
pliance.
4)  Replace the screw holding the plate just 
before completely pushing the appliance into 
the fi replace.
INSTALLATION
For 
PROPANE
 Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.