Regency P40 Benutzerhandbuch

Seite von 48
Regency
®
 P40 Direct Vent Gas Fireplace
41
MAINTENANCE
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Power Module
3)  Remove the Power Module cover by 
removing the 2 screws, one on each side 
of the box.
4)  Unplug all wires connected to the Power 
Module (J1, J2 & J3 on the power module 
circuit board).
5)  Pull Power Module off of pins and replace.
6)  Reverse steps to re-install. 
Power Module
3)  Remove the Control Module by lifting it up 
off of the velcro and pull out.
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Control Module
4)  Remove the Heat Shield from the Control 
Module by removing the 2 screws.
Heat Shield
5)  Unplug all wire harnesses and manual 
control box cable plugged into the Control 
module.
6)  Replace the Control Module and reverse 
steps to re-install. 
POWER MODULE 
REPLACEMENT
CONTROL MODULE 
REPLACEMENT
MAINTENANCE
J1
J2
J3
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Power Module
3)  Remove the Power Module cover by 
removing the 2 screws, one on each side 
of the box.
4)  Replace the 9V and AA battery and reverse 
steps to re-install.
BACKUP BATTERY 
REPLACEMENT
(within Power Module)
NOTE:  The 9V battery operates the rear 
burner and the AA battery operates 
the DC Sparker for lighting the pilot 
under power outage conditions.