Appliance Set-Up
A.  Leveling System
B. Outside Air Kit Instructions 
Parts Included in Kit: 1 piece of 51mm x 914mm flex
hose, 2 hose clamps, 1 collar assembly, 1 termination cap
assembly, 1 trim ring, fasteners and air intake channel
(discard).
1.  Measure distance from floor to air vent opening in appli-
ance and mark location on wall.
2.  Use saw to cut opening in wall. Cut a 64 to 76mm open-
ing on inside wall and a 76 to 89mm opening on outside
of house.
3.  Use hose clamp to secure flex pipe to collar assembly.
4.  Slide trim ring over flex pipe and run pipe through wall.
5.  Attach  hose  to  outside  termination  cap  with  second
hose clamp.
6.  Secure termination cap to outside surface.
7.  Secure trim ring to interior wall.
Tools Needed: Phillips head screwdriver; wire cutters;
hole saw or jig saw.
CAUTION
Never draw outside combustion air from:
•  Wall, floor or ceiling cavity
•  Enclosed space such as an attic or garage
The leveling bolts are located at the rear of the appliance.
To access the bolts, remove the side access panels. Reach
in and turn the bolt to the desired height to level the appli-
ance. Shown in
Figures 31.1 and 31.2.
Figure 31.1
Leveling Bolt on each Side
Flex Hose 
Hose Clamp 
Collar  
Assembly 
Hose Clamp 
Trim Ring
Termination 
Cap Assembly
Air Intake Channel (Discard)
Figure 31.2 (Shown on Castile Insert)
2 inch diameter Flex Pipe
Attach Termination 
Cap to Exterior Wall
Leveling Bolt