GN National Electric BP)-1 Benutzerhandbuch

Seite von 48
22618-4-1106
Page 10
1.  Pick a location on a wall with a clear space in the room. In 
selecting a location for installation, it is necessary to provide 
adequate  accessibility  clearances  for  servicing  and  proper 
installation. Be sure to locate the unit close enough to a 115 
VAC wall receptacle to properly power appliance.
2.  When facing the front of the furnace, the minimum clearances 
from casing to combustible construction are 0” (0mm) on top, 
0” (0mm) on each side, recommend 4” (102mm) on right side 
for serving and 0” (0mm) from the floor and 2” (51mm) to rear 
wall.
3.  The minimum distance from the center of the vent cap to the 
nearest outside corner or obstruction is 12” (305mm).
The bottom of the exhaust vent terminal and the air intake shall 
be located at least 12” (305mm) above grade and must be vented 
outside.
WARNING: The nearest point of the vent cap should be a 
minimum horizontal distance of six (6) feet (1.83m) from 
any pressure regulator. In case of regulator malfunction, 
the six (6) feet (1.83m) distance will reduce the chance of 
gas entering the vent cap.
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or other 
combustible material, other than wood flooring, the appliance shall 
be installed on a metal or wood panel extending the full width and 
depth of the appliance.
The base referred to above does not mean the fire-proof base as 
used on wood stoves. The protection is primarily for rugs that may 
be extremely thick and light-color tile that can discolor.
Locating Wall Opening 
The recommended location for this heater is on an outside wall (the 
unit can be located on an inside wall but must not exceed 20’ (6.096m) 
in exhaust vent length). Locate wall studs so that wall vent opening 
will be located between wall studs. The wall opening required for 
venting is a 1 7/8” (48mm) minimum diameter opening. 
Refer to Figures 3 to 6 for positioning the heater on wall and for 
locating gas line connection and vent opening. Heater can sit on 
the floor.
CLEARANCES FOR SINGLE FLUE
HEATER INSTALLATION FOR SINGLE FLUE