LIGHTING INSTRUCTIONS
1.  Main Electrical power supply must always be switched on to 
the unit with the two burner switches in the off position (up) 
before lighting the heater.
2.  Turn on main gas supply.
3.  Verify that main electrical supply is switched on by checking 
the 115V AC power status display (Figures 32 and 33) indica-
tor is on.
4.  Burner  selection:  select  low  burn  (front  burner),  medium 
burn  (rear  burner),  or  high  burn  (both  burners).  Low  burn 
switch  (Figure  32)  controls  the  front  burner  only.  Medium 
burn switch (Figure 33) controls the rear burner only. When 
both switches are down, they will activate both the low and 
medium burners, which is the high setting.
5.  Heater operating LED sequence (Front Display Panel). Be-
fore starting ensure that the power L.E.D (Figure 34A) is on 
and burner switches are off. Switch on the heater by engag-
ing the low and medium burner switch, this will activate the 
pressure switch and the exhaust fan L.E.D (Figure 34E) will 
be on. Also the two burner L.E.D’s (Figure 34C and 34D) 
will start flashing for 35 seconds prior to ignition. Once both 
burners have ignited, the burner L.E.D’s will remain on. If 
you can’t see flame on the rear burner, but the burner L.E.D 
is on, then there will be flame there which will become more 
visible as the heater warms up. Once the heater warms up 
the low speed L.E.D (Figure 34F) will light and the convec-
tion fan will blow warm air from the heater. As the heater 
becomes warmer, the medium L.E.D (Figure 34G) will come 
on. When the heater has reached its highest operating tem-
perature, all three L.E.D’s will light up and the convection 
fan will now be running at its high speed. Refer to page 30 
- Fan Operation. When the heater has been running for some 
time, the water pump L.E.D (Figure 34B) may come on to 
signal  that  the  pump  has  been  activated.  Refer  to  page  33 
- Automatic Humidifier Operation.
Note: Three heat settings are available for operating your Mantis 
heater - low, medium and high.
 
a.  Low setting (front burner only) - engage low burn switch 
only (Figure 32)
 
b.  Medium  setting  (rear  burner  only)  -  engage  medium 
burner switch only (Figure 33)
 
c.  High setting (front and rear burners).
Caution:  When switching from the front burner to the rear burner, be sure to activate the rear burner first, then turn off the front burner. 
When switching from rear burner to the front burner, be sure to activate the front burner first. Simple rule - always activate the 
desired burner first, then switch the other burner off. If it is switched the wrong way, the burner(s) will go out and the heater 
may need to be reset. Refer to page 38 - Resetting the Heater.