WIRING
(1)
(2) BLACK
BLACK (3)
(4) RED
YELLOW (5)
(6) RED
BLUE (7)
(8) BROWN
GREY (9)
(10) RED
RED (11)
(12) BLACK
BLACK (13)
(14) RED
RED (15)
(16) FRONT H.S.I.
FRONT H.S.I. (17)
(18) REAR H.S.I.
REAR H.S.I. (19)
(20) BROWN
WHITE (3-5-7)
(1) BLUE
BLACK (8)
(2) BLACK
(15) ORANGE
(13) RED
(11) BLACK
(9) BROWN
(7) PURPLE
(5) BLUE
(3) WHITE
(1) YELLOW
GREEN/YELLOW (16)
BLACK (14)
BLACK (12)
GREEN (10)
RED (8)
RED (6)
BLACK (4)
RED (2)
(5) YELLOW
(3) BLACK
(1) GREY
ORANGE (6)
WHITE (4)
RED (2)
WATER LEVEL
SWITCH
TRANSFORMER
14 WAY RIBBON TO
FRONT PANEL DISPLAY
FRONT BURNER
SWITCH
REAR BURNER
SWITCH
THERMISTOR
P1 TO
DISPLAY
P1 TO
DISPLAY
AIR PRESSURE
SWITCH
PIN 5
(NC)
(NO)
(COM)
TRANSFORMER
120V BLACK
PINS 4 OR 6
CONV. FAN
PIN 13
GAS VALVE
80 C
VALVE /
INDP
FLUE FAN
PIN 3
PIN 6
PIN 4
120V WHITE
HSI
PIN 18
PIN 16
PIN 20
PIN 5
CONDENSATE
PUMP
WIRING DIAGRAM
WHITE
BLACK
ORANGE
ORANGE
BLACK
BLACK
ORANGE
YELLOW
TRANSFORMER
TO JUNCTION BLOCK
YELLOW
BLUE
BLUE
BROWN
BROWN
F
R
GREY
4 µF
3 µF
14 WAY RIBBON TO
CONTROL MODULE
P1
T1
T2
P2
OPTIONAL
CONTROL
WIRING
RECEIVER
BLACK
WHITE
PURPLE
YELLOW
BLUE
WHITE
WHITE
BLACK
RED
R. BRN. THERM (4)
L. BRN. THERM (3)
BLACK
BLUE
WHITE
RED
BLUE
JUNCTION
BLOCK
TO
TRANSFORMER
BLUE
INDICATOR
SWITCH
BLACK
WHITE
WHITE
+ -
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, with 
the National Electrical Code, ANSI/NFPA 70 or Canadian Electri-
cal Code, CSA C22.1, if an external electrical source is utilized. 
This  appliance  is  equipped  with  a  three-prong  [grounding] 
plug for your protection against shock hazard and should be 
plugged directly into a properly grounded three-prong recep-
tacle.  Do  not  cut  or  remove  the  grounding  prong  from  this 
plug. For an ungrounded receptacle, an adapter, which has two 
prongs and a wire for grounding, can be purchased, plugged into 
the ungrounded receptacle and its wire connected to the recep-
tacle mounting screw. With this wire completing the ground, the 
appliance cord plug can be plugged into the adapter and be electri-
cally grounded.
CAUTION: Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing. 
Note: For testing flame sensor circuit use a micro-amp meter in 
series with sensor. Minimum current should be 1 micro-amp dur-
ing operation. Be careful as flame sensor is in the 115VAC circuit. 
If current is below 1 micro-amp, remove sensor, clean with light 
sandpaper and retest.
Note:  This  heater  is  equipped  with  a  remote  bulb  electronic 
thermistor  control  located  low  on  the  back  of  the  furnace. 
Sometimes due to field locations different air currents may ef-
fect the control sensing of the thermistor. This sensing bulb can 
be re-located if necessary to provide for better air sensing and 
control.
Figure 44
Figure 45