Attention: Wiring harness on blower is factory assembled and 
installed. If wiring harness becomes disassembled, use the fol-
lowing steps to reassemble the wiring harness.
1. Attach (1) pin terminal from black (hot) wire, smooth insulation 
on cord set to (1) socket terminal on fan control assembly.
2. Attach (1) pin terminal from black (neutral) wire, ribbed insu-
lation on cord set to (1) socket terminal from white (neutral) 
wire on motor.
3. Attach (1) pin terminal on fan control assembly to (1) socket 
terminal from black (hot) wire on motor.
4. Attach green ground wire beneath one of the #10 x 1/2” (13mm) 
screws on the blower housing.
Fan Control
The automatic fan control is located in the switch box. The switch 
box is attached to the front of the blower assembly. The switch box 
is adjacent to the combustion chamber. The fan control is a non-
adjustable automatic type. The fan control will require between 
5 and 10 minutes of main burner operation before the fan control 
“closes” and activates the blower. The blower will continue to run 
between 5 and 10 minutes after the main burner shuts off, before 
the fan control “opens” and deactivates the blower.
Index 
No.
Part 
No.
Description
1
11727
Blower Housing and Chute Assembly
2
9120106
Fan Control Switch
3
RH-863
Switch Box
4
DV-807
Switch Box Cover
5
R-2091
Wire Assembly
6
642031
Blower Wheel
7
11728
Motor Mounting Plate
8
632016
Motor Cushion
9
R-2605
Motor
10
8720161
Strain Relief Bushing
11
R-2099
Cord Set
12
RH-138
Blower Cushion
Wiring
The appliance, when installed, must be electrically grounded in ac-
cordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical 
Code, CSA C22.1, if an external electrical source is utilized. This 
appliance is equipped with a three-prong [grounding] plug for 
your protection against shock hazard and should be plugged 
directly into a properly grounded three-prong receptacle. Do 
not cut or remove the grounding prong from this plug. For an 
ungrounded receptacle, an adapter, which has two prongs and a 
wire for grounding, can be purchased, plugged into the ungrounded 
receptacle and its wire connected to the receptacle mounting screws. 
With this wire completing the ground, the appliance cord plug can 
be plugged into the adapter and be electrically grounded. A 7/8” 
(22mm) hole is provided in the junction box for use with a conduit 
connector if local codes require this type of protection.
Wiring Diagram
If any of the original wire as supplied with the appliance must be 
replaced, it must be replaced with type 125
o
C wire or its equiva-
lent.
Cleaning
The blower wheel will collect lint and could require cleaning once 
a year. If the air output decreases or the noise level increases, it 
indicates a dirty wheel. Complete removal of the wheel and scrub-
bing it with a brush under flowing water is recommended.
Oiling
The blower motor has an oil hole located on each end of the motor. 
Use #20 motor oil only. It is best to oil the motor several times during 
the heating season using 2 or 3 drops each time. If the motor fails 
to start and hums, it could be a tight bearing due to lack of oil. This 
may be corrected by pouring kerosene in the oil holes, allowing to 
stand for a few hours and then oiling properly.
CAUTION: Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper and danger-
ous operation. Verify proper operation after servicing.
Warning:
Unplugging of blower accessory will not stop the heater 
from cycling. To shut heater off:
1. Turn temperature dial or thermostat to lowest setting.
2. Turn knob n gas control to “OFF,” depressing slightly. 
Do not force.