BLOWER ACCESSORY INFORMATION
The  appliance,  when  installed  must  be  electrically  connected 
and grounded in accordance with local codes or, in the absence 
of local codes, with the current CSA C22.1 Canadian Electrical 
Code.
U.S. Installations, follow local codes and the National Electrical 
Code, ANSI/NFPA No. 70.
Should this blower require servicing, the power supply must be 
disconnected. For rewiring of any replacement components, re-
fer to Figures 16 and 17 and the parts list on page 25.
BLOWER ACCESSORY
Operation
The fireplace insert is equipped with a factory installed blower accessory 
that includes a fan control switch, plus a rheostat (speed control).
The speed control knob is located behind the lower louver  at the right 
side of the insert.
From  a  cold  start,  the  temperature  activated  fan  control  switch  will 
normally take 5-10 minutes to heat up and energize the blower.
Once the blower is energized, adjust the blower speed  control as desired, 
then replace the lower louver.
When the insert is shut off, it may take 30-40 minutes for  the heated unit 
to dissipate (cool down) enough for the blower to shut off automatically. 
Note: The  blower  shut  off  times  will  vary  on  blower  speed  and  BTU 
input level setting control by adjustment of the HI/LO knob located on 
the gas valve.
Blower removal instructions
Servicing  or  removal  of  the  blower  system  must  be  performed  by  a 
qualified service person. 
If the blower assembly (Item 45, page 24) must be replaced, the following  
steps are recommended for removal:
1.  Turn off gas and disconnect the electrical supply.
2.  Remove the glass door assembly.
3.  Remove the log set.
4.  Remove the front surround panel assembly by lifting upward and 
outward to detach.
5.  Remove the 5/16” x 2-1/2” center bolt that retains the  Vent Slide 
plate assembly.  
6.  Remove the insert from the fireplace cavity by pulling forward on 
the insert, and at the same time, sliding the vent plate rearward until 
disengaged.
7.  As  the  insert  is  moved  outward,  the  gas  line  may  need  to  be 
disconnected at the insert shut off valve.  If so,  make sure the main 
gas line is shut off that supplies gas to the insert.
8.  Once the insert is pulled out, the blower assembly can be removed 
by locating the (6) screws on the lower back of the insert that retains 
the blower base plate.
9.  When  the  screws  are  removed,  gently  pull  the  blower  assembly 
outward.  
10.  Disconnect the two ¼” wire terminals from the motor.
11.  Remove the (4) screws that retain the blower assembly to the base 
plate, and set blower aside.
12.  Install the replacement blower, and re-install the insert by reversing 
above steps.
Figure 16