John Deere AC-100LP Benutzerhandbuch

Seite von 68
14 
 
Operator’s Manual
Symptom 
Problem 
Solution
 
Fan does not turn when heater  
 
   
 
 
 
 
is plugged in.
 
 
Heater will not ignite.
No electrical power to heater.
 
Fan hitting inside of heater shell.
 
Fan blades bent.
Defective motor. 
 
 
User did not follow installation or 
operation instructions properly. 
 
No spark at ignitor. To test for spark, 
see "Service: Ignitor" and follow 
step 8. If you see spark at ignitor, 
have heater serviced by qualified 
service person. If no spark seen:
a. Loose or disconnected ignitor  
    wire
b. Wrong spark gap
c. Bad ignitor electrode 
d. Bad spark transformer
Check voltage to electrical outlet. If volt-
age is good, check heater power cord 
for breaks. 
 
Adjust motor / fan mount to keep fan 
from hitting inside of heater shell. 
 
Replace fan.  
 
Replace motor.  
 
 
Repeat installation and operation 
instructions. 
 
 
 
 
 
a. Check ignitor wire. Tighten or reattach  
    loose ignitor wire. See "Maintenance:     
    Spark Transformer" for ignitor wire     
    location
b. Set gap between ignitor electrode and  
    nozzle to .13"/.15" (3.3/3.8 mm)
c. Replace ignitor electrode. See 
    "Maintenance: Ignitor".
d. Replace spark transformer. See 
    "Maintenance: Spark Transformer".
Troubleshooting
  WARNING: HIGH VOLTAGE. NEVER SERVICE SPACE HEATER WHILE IT IS PLUGGED IN,  
 
      OPERATING, OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.