Homelite UT65052-A Benutzerhandbuch
7
101568
3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT:
Extra hose or piping may be used if needed. Install extra hose
or piping between hose/regulator assembly and propane tank. You must use
the regulator supplied with heater.
the regulator supplied with heater.
4. Open propane supply valve on propane tank(s) slowly.
Note:
If not opened
slowly, excess-flow check valve on propane tank may stop gas flow. If this
happens, close propane supply valve and open again slowly.
happens, close propane supply valve and open again slowly.
5. Check all connections for leaks.
Figure 4 - Hose and Inlet Connector
Generic LP 155
LP-PFA/P 022B
Hose
Inlet Connector
VENTILATION
!
WARNING
Follow the minimum fresh, outside air ventilation require-
ments. If proper fresh, outside air ventilation is not provided,
carbon monoxide poisoning can occur. Provide proper fresh,
outside air ventilation before running heater.
ments. If proper fresh, outside air ventilation is not provided,
carbon monoxide poisoning can occur. Provide proper fresh,
outside air ventilation before running heater.
Provide a fresh air opening of at least four and one half (4.5) square feet. Provide
extra fresh air if more heaters are being used.
extra fresh air if more heaters are being used.
Example:
A 150,000 BTU/Hr heater requires one of the following:
• a two-car garage door raised six inches
• a single-car garage door raised nine inches
• two thirty-inch windows raised twelve inches
• a single-car garage door raised nine inches
• two thirty-inch windows raised twelve inches
!
WARNING
Never use an open flame to check for a leak. Apply a mixture
of liquid soap and water to all joints. Bubbles forming show a
leak. Correct all leaks at once.
of liquid soap and water to all joints. Bubbles forming show a
leak. Correct all leaks at once.
6. Close propane supply valve.