Appendix A: Fuel Conversion
CONVERTING THE CLARITY FIREPLACE
INSERT FROM ONE GAS TO ANOTHER IN
THE FIELD
NOTE:  THE  CONVERSION  SHALL  BE  CAR-
RIED  OUT  IN  ACCORDANCE  WITH  THE  RE-
QUIREMENTS  OF  THE  PROVINCIAL  OR  LO-
CAL  AUTHORITIES  HAVING  JURISDICTION
AND  IN  A CC OR DA NC E  WITH  R EQUIRE-
MENTS  OF  THE  CURRENT  EDITION  OF  THE
NATIONAL  FUEL  GAS  CODE,  ANSI  Z223.1  or
the  CAN/CGA-B149  INSTALLATION  CODES.
CONVERSION KIT COMPONENTS
• Burner system module
• Conversion label
The Clarity Fireplace Insert  is designed to burn
either  natural  gas  or  propane,  but  requires  a  dedi-
cated burner system module for either fuel. Conver-
sion to the alternate fuel is a simple matter of replac-
ing one burner system module with another. A label
on the burner system module will specify for which
fuel it is intended.
To  accomplish  the  conversion  procedure,  follow
these steps.
1.  Remove  the trim  panels  and  the glass  door  ac-
cording to the directions on page 12.
2. Disconnect the electrical connections and the gas
line fitting from the module.
3. Remove the cross log, the front logs, and the two
ember strips following the directions on page 7.
4. Pull the module out an inch or so so that there is
enough room to remove the rear log.
5. Remove the Burner System Module
The module can be removed as an integrated unit
by simply pulling the module forward.
6. Install the replacement module, re-install the logs,
re-connect  the  wiring  connections  and  gas  line  fit-
ting, secure the glass door, and replace the trim pan-
els.
After  completing  the fuel  conversion,  an  installer
fuel  label—supplied  with  the  burner  system  mod-
ule—must be filled out by the installer and attached
to the stove.
SEE WIRING DIAGRAM ON PAGE 18
The above label on the Clarity's burner system module indicates
that the unit is equipped to burn natural gas. A similar label is
used for Propane.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ER-
RORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION.  VERIFY PROPER OPERATION AFTER
SERVICING.
PROPANE
NATURAL
HARMAN  CLARIT Y  GAS
FI REPLACE  INSERT