Remove  the  chimney  cap  if  one  exists  so  that  the
flue may be cleaned and the venting installed.
Remove  any  existing  hearth  accessories  such  as
glass doors, spark screens, andirons, and grates.
Clean the chimney thoroughly to remove ash, soot,
and any obstructions, and then clean ash, soot, dust,
and debris from the fireplace.
The  damper  must  be  locked open  to  allow  the  4"
venting to pass through. If it is necessary to modify
the damper area to allow passage of the venting, the
modifications should be allowed under local codes.
Confirm  any  planned  changes  with  local  building
officials.
VENTING
Use  Only  Approved  Venting
The  Clarity  828I  Vented  Gas  Fireplace  Insert  is
tested  and  listed  for  connection  to  a  4"  (100  mm)
listed Class B venting system.
If the unit is installed to vent through an approved
masonry chimney or a factory-built chimney system,
a listed lining system approved for use with gas-fired
appliances must be used.
Observe  local  codes  when  venting  the  Clarity.  If
no local codes exist, follow the current edition of ANSI
Z223.1  and CAN1-  B149 installation  codes.
Do  not  connect  the  venting to  the  flue  of  a  chim-
ney that serves a  separate solid-fuel burning appli-
ance.
The venting manufacturer's installation instructions
must be followed exactly.
IMPORTANT: Because of the high efficiency and
low  flue  gas  temperatures  of  this  appliance,  it  is
important that it be connected to a well-sealed and
efficient venting system which is capable of regis-
tering a negative pressure while the stove is in op-
eration.
The  most  efficient  venting  systems  are  those  that
have a minimum number of bends and minimal hori-
zontal  runs.
The Clarity Fireplace Insert  is equipped with a ther-
mally  activated  vent  safety  switch  which  will  shut
down  the  main burner  if  the  heater is  not  properly
venting.  The  safety  switch  will  automatically  reset
after the heater  has cooled down.
The switch  will continue  to cycle  off and  on until
the  venting problem  is corrected.  If  you are  unable
to  correct  the  venting  problem,  seek  expert  advice
from your Harman dealer or installer.
DO  NOT  DISCONNECT  OR  BYPA SS  THE
VENT  SAFETY  SWITCH.
WARNING:  Operation  of  this  heater  when  not
connected  to a  properly  installed and  maintained
venting  system or  tampering with  the vent  safety
shutoff system can result in carbon monoxide (CO)
poisoning and possible death.
The Clarity Fireplace Insert is equipped with its own
integral  draft  hood  so  no  additional  draft  hood  is
required. The heater  should be installed so  that the
draft hood is in the same atmospheric pressure zone
as the air inlets to the heater.
TEST FOR FLUE SPILLAGE
A  spillage  test  should  always  be  made  at  the
completion of the installation, and at least annually
thereafter.
1. Start all exhaust fans in the home and then close
all  doors  and  windows  in  the  room  containing  the
heater.
2.  Light  the  heater  and  allow  it  to  run  for  5  min-
utes  on  the  high output  setting.  The  convection  air
blower should be turned off for the test.
3. Remove the left trim panel, which is held in place
by a clip at the bottom and a magnet at the top, and
place a source of smoke (such as a match, lighter, or
a cigarette) in front of the flue spillage test tube.
The  smoke should  be drawn  into  the tube.  If it  is
not, let the heater run for 5 more minutes and repeat
the test.
4. If the smoke is not drawn into the tube, turn off
the  heater  and  determine  why  there  is  no  draft.  If
necessary, seek expert advice.
For sites with swirling or turbulent wind condi-
tions, a wind cap may solve the problem.
CONNECTING THE CLARITY FIREPLACE
Remove Left Wing
Cover to Expose
Draft Tube.
Draft Tube