The Clarity  Fireplace Insert, when  installed, must
be  electrically  grounded  in  accordance  with  local
codes or, in the absence of  local codes, with the the
current  edition  of  the  National  Electrical  Code,
ANSI/NFPA  70  in  the United  States  or  the  current
Canadian  Electrical  Code  CSA  22.1  in  Canada.
This  appliance  is  equipped  with  a  three-prong
(grounding)  plug for  protection  against shock  haz-
ard and should be plugged  directly into a properly
grounded  three-prong  receptacle.  Do not  cut  or  re-
move the grounding prong from the plug.
NOTE:  The  convection  fan  requires  a  120  VAC
supply for operation, but the heater can be operated
without the fan as in the case of a power outage.
Plug  the  3-prong  grounded  electrical  cord  plug
into the wall outlet.
CONNECTING THE
OPTIONAL THERMOSTAT
If  the  optional  thermostat  is  used,  it  must  be
plugged  into  the  terminal  strip  located  behind  the
right  side  air  inlet  grill.  It  can  be  accessed  by  first
opening the control access door and then pulling up
and forward on the air grill. The terminal block will
then be visible.
When  installing  a  millivolt  control  system,  use
only a special low resistance thermostat. Do not use
a regular heating thermostat.
Be  sure  that  all  electrical  connections  are  clean,
free  from  corrosion,  and  tight.  Inspect  connections
periodically  to  confirm  that  no  corrosion  has  built
up over time.
When properly installed and maintained, a mil-
livolt  control  system  should  give  many  years  of
trouble-free service.
It is important to use wire of a gauge proper for
the length of the wire:
RECOMMENDED  WIRE  GAUGES
Maximum
Wire
Length
Gauge
100'
14
60'
16
40'
18
25'
20
15'
22
INSTALLING THE INSERT
BEFORE  OPERATING
Gas  Pressure  Requirements
Correct  gas  pressure  and  the  use  of  a  properly
sized gas supply  line are essential  for  the safe and
efficient  performance  of  this  appliance.  Make  sure
that the plumber or gas supplier checks the gas sup-
ply line and gas pressure at installation.
 NOTE: Improper gas pressure can affect heater
performance, flame color, or cause pilot outage.
Natural  Gas:
Maximum inlet pressure 7.0" w.c. (1.74 kPa)
Minimum inlet  pressure 5.0"  w.c. (1.25  kPa)
Gas manifold pressure 3.5" w.c. (0.87 kPa)
LPG  Gas:
Maximum  inlet  pressure 13"  w.c.  (3.24  kPa)
Minimum  inlet  pressure  11"  w.c.  (2.74  kPa)
Gas manifold pressure 10" w.c. (2.49 kPa)
DO NOT USE THIS HEATER IF ANY PART HAS
BEEN  UNDER  WATER  OR  EXPOSED  TO  MOIS-
TURE  CORROSION.  IM MED IATELY  CALL  A
QUALlFlED  SERVICE TECHNICIAN  TO  INSPECT
THE HEATER AND REPLACE ANY PART OF THE
CONTROL  SYSTEM  AND  ANY  GAS  CONTROL
WHICH  HAS BEEN  UNDER  WATER.
NE PAS SE SERVIR DE CET APPAREIL S'IL A ÉTRE
PLONGÉ DANS L'EAU, COMPLÉTEMENT OU EN
PARTIE. APPELER UN TECHNICIEN QUALIFIÉ
POUR INSPECTER L'APPAREIL ET REMPLACER
TOUTE PARTIE DU SYSTÈME DE CONTRÔLE ET
TOUTE COMMANDE QUI ONT ÉTÉ PLONGÉS DANS
L'LAU.
CONNECTING THE CORDSET
Pipe  Length
Schedule  40  Pipe
Tubing,  Type  L
(Feet)
Inside  Diameter
Outside  Diameter
N.G.
L.P.
N.G.
L.P.
0-10
1/2"
3/8"
1/2"
3/8"
1.3  cm
1.0  cm
1.3  cm
1.0  cm
10-40
1/2"
1/2"
5/8"
1/2"
1.3  cm
1.3  cm
1.6  cm
1.3  cm
40-100
1/2"
1/2"
3/4"
1/2"
1.3  cm
1.3  cm
1.6  cm
1.3  cm
100-150
3/4"
1/2"
7/8"
3/4"
2.0  cm
1.3  cm
2.3  cm
2.0  cm
RECOMMENDED  GAS  PIPE  DIAMETER
NOTE:  NEVER  USE  PLASTIC  PIPE.  CHECK  TO
CONFIRM  WHETHER  YOUR  LOCAL  CODES  ALLOW
COPPER  TUBING  OR  GALVANIZED  PIPE.