Fireplace Installation 
fasteners.  attach supplied wall 
cover brackets to the top and the 
bottom of fireplace to cover the 
gap on the dry wall (Figure 8).
 
Attach fireplace frame as 
shown in Figure 4
.
Bathroom Installation
This firebox must be protected 
by a GFI receptacle or circuit 
for bathroom use.  If receptacle 
Fireplace
Junction
Box
White wire (n)
Black wire (L)
Green wire (G)
Green wire (G)
Black wire (L)
White wire (n)
120 V Power 
supply 
(Breaker Panel)
is used it must be readily 
accessible.
This unit is an electrical appliance 
that is not watertight and must 
be installed as to prevent water 
from entering the unit to prevent 
electrical shock.  This unit must 
be installed away from showers, 
tubs, etc.
Never locate fireplace where it 
may fall into a bathtub or other 
water containers.  Keep towels 
and other combustible materials 
three (3) feet (0.9 m) away from 
the bottom of the unit.
The controls are located on the 
right hand side of the fireplace 
(Figure 9). 
add 
wood 
screws 
here
Figure 8