trOUbLeShOOting
Continued
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
pOSSIBLE CAUSE
1. Gas  leak. 
See  Warning 
statement at top of page
2. Control valve defective
1. Foreign  matter  between 
control valve and burner
2. Gas  leak. 
See  Warning 
statement at top of page
1. Debris  around  burner  air 
mixer
2. Improper vent configuration
1. Air  holes  at  burner  inlet 
blocked
2. Burner flame holes blocked
3. Improper venting or exces-
sive blockage
4. Excessive amounts of em-
bers and pan material
OBSERVED PROBLEM
Gas  odor  even  when  gas 
control valve is off
Gas odor during combustion
Glass soots
Dark residue on logs or inside 
of fireplace
REMEDY
1. Locate and correct all leaks 
(see  Checking  Gas  Con-
nections, page 18)
2. Replace control valve
1. Take apart gas tubing and 
remove foreign matter
2. Locate and correct all leaks 
(see  Checking  Gas  Con-
nections, page 18)
1. Inspect opening at base of 
burner to see that it is NOT 
packed  with  any  type  of 
material
2. Check  vent  configuration 
specification  (see  Venting 
Installation, page 10)
1. Clean out air holes at burn-
er inlets. Periodically repeat 
as needed
2. Remove blockage
3. Have vent system inspect-
ed,  including  termination 
cap.  Remove  any  restric-
tions or obstruction
4. Clear excess embers until 
a  minimum  gap  of  1/2" 
remains under grate