Dimplex BF45DXP Benutzerhandbuch

Seite von 14
8  
www.dimplex.com
 Maintenance
 WARNINg:  Disconnect all 
power coming to fireplace at main 
service panel before attempting 
maintenance or cleaning to 
reduce risk of fire, shock or 
damage to persons.
 CAUTION: 
Allow at least 5 
minutes for light bulbs to cool off 
before touching bulbs to avoid ac-
cidental burning of skin.  
Tool Requirements: Phillips 
screwdriver
Light Bulb Replacement: 
Light bulbs need to be replaced 
when you notice a dark section 
of the flame or when the clarity 
and detail of the log exterior 
disappears.  There are four bulbs 
under the log set which generate 
the flames and embers.
Helpful Hints: It is a good idea to 
replace all light bulbs at one time 
if they are close to the end of their 
rated life.  Group replacement will 
reduce the number of times you 
need to open the unit to replace 
light bulbs.  Long life bulbs are 
recommended to reduce the 
frequency of bulb changes.
Light Bulb Requirements: 
Quantity of 4 clear chandelier or 
candelabra bulbs with an E-12 
(small) socket base, 60 Watt 
rating.  Example: GE 60BC or 
Philips 60CTC. 
DO NOT EXCEED 60 WATTS 
PER BULB.
 CAUTION:  When handling log 
only apply force to the ember bed 
section not directly to the logs.
To access the light bulb area
open steel curtain (remove 
1. 
glass doors if applicable).
remove two screws on log 
2. 
bracket and set aside 
(Figure 2)
Pull front edge of plastic 
3. 
ember bed or plastic grate 
up and forward until rear 
tab releases from the ledge 
located at the bottom of the 
mirror (Figure 3).
!
 NOTE: Log set fits tightly 
into firebox, some force may be 
necessary to remove.
screws
Figure 2