OPERATING FIREPLACE
MILLIVOLT
FOR YOUR SAFETY  
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
  A. This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BeFore LiGhTiNG smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
  WhAT To Do iF YoU SMeLL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use 
any phone in your building.
• immediately call your gas supplier from 
a  neighbor’s  phone.  Follow  the  gas 
supplier’s instructions.
• if you cannot reach your gas supplier, call the 
fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. if the 
knob will not push in or turn by hand, don’t 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
CLEANING AND REPLACING 
GLASS DOOR
Note:
 Before proceeding, make sure unit is com-
pletely cool.
1.  Remove top and bottom louvers and screen 
assembly. Undo 4 latches and open glass door.  
The procedure is the same for the end lover 
panel but the entire frame must be removed 
as one assembly.
2.  To clean glass door, DO NOT remove glass 
from frame. Use any glass cleaner to clean 
glass. Do not use abrasive cleaners as this may 
damage glass.
3.  If replacement is necessary, the entire assem-
bly (frame and glass) must be replaced. If glass 
is broken, wear gloves and tape remaining 
fragments onto the frame. Remove 5 screws 
located on end of firebox while holding frame 
assembly to prevent it from falling  and caus-
ing injury (see Figure 57). Mount new frame 
at hinge with 5 new screws. Close and latch 
door. This will seat the gasket. If replacing end 
glass panel, remove 16 screws around frame  
(see Figure 58) To insure proper fit, when 
installing new glass panels make sure seam 
in gasket is placed in the down position.
4.  Replace screen assembly and top and bottom 
louvers.
OPERATING GUIDELINES 
AND MAINTENANCE 
INSTRUCTIONS
Continued
Figure 57 - Removing Glass Door
Figure 58 - End Panel Replacement
Glass 
Assembly
Frame 
Assembly
Louver Assembly
Retainer Screws
Screws
Hinge